User`s guide
Table Of Contents
- User’s Guide
- 1 Getting Started
- 2 Introduction
- 3 Installation
- 4 Using EasyEXPERT
- 5 Classic Test Definition
- I/V Sweep
- Multi Channel I/V Sweep
- I/V List Sweep
- I/V-t Sampling
- C-V Sweep
- Direct Control
- Function Setup
- Auto Analysis Setup
- Display Setup
- SMU Range Setup Window
- ADC and Integration Time Setup Window
- Advanced Setup Window
- CMU Range Setup Window
- Advanced Setup Window for C-V Sweep
- Switching Matrix Control
- SPGU Control
- SPGU Pulse Setup Window
- Load Z Setup Window
- Pulse Switch Setup Window
- SPGU ALWG Setup Window
- Define ALWG Waveform Window
- 6 Application Test Definition
- 7 Function Details
- I/V Sweep Measurement
- Multi Channel I/V Sweep Measurement
- I/V-t Sampling Measurement
- C-V Sweep Measurement
- SPGU Module
- Sweep Abort Function
- Standby Function
- Bias Hold Function
- Current Offset Cancel
- SMU CMU Unify Unit
- Atto Sense and Switch Unit
- SMU/PG Selector
- SMU Ranging Mode
- SMU Compliance
- SMU Pulse
- SMU Measurement Time
- SMU Filter
- SMU Series Resistor
- Interlock Function
- Auto Power Off Function
- Initial Settings
- 8 Built-in Programming Tool
- 9 If You Have a Problem
- When You Operate B1500A
- When You Perform Measurement
- Measurement Takes More Time than Specified
- Noise Affects the Measured Values
- Voltage Measurement Error is Large
- SMU Oscillates for High-Frequency Device Measurements
- SMU Oscillates for Negative Resistance Measurements
- Large Current Causes High Temperature (Thermal Drift)
- Measurement Damages the Device under Test
- Leaving Connections Damages Devices after Measurement
- Unexpected Sampling Measurement Data is Returned
- MFCMU Causes Unbalance Condition
- Before Shipping to Service Center
- Data Backup and Recovery
- B1500A System Recovery
- Updating EasyEXPERT
- Error Codes
- 10 Application Library and Utilities

10-18 Agilent B1500 User’s Guide, Edition 7
Application Library and Utilities
QSCV Measurement Supplemental Data
Table 10-2 Constant Value for Calculating the Measurement Accuracy: HRSMU/ASU
Measurement
Range Constant
Voltage Output Range
QSCV Operating
Mode
0.5 V 2 V 5 V 20 V 40 V 100 V
10 pA Ap 0.47 0.47 0.47 0.47 0.48 0.48
Bp 0.014 0.029 0.051 0.15 0.30 0.72 Normal
0.009 0.011 0.015 0.03 0.06 0.13 4155C/4156C
compatible
Cp 0.013
Dp 0.001
Ao 0.04 Normal
0.07 4155C/4156C
compatible
Bo 1.3E-16
Boc 1.1E-05
Co 5.4E-15
Coc 2.4E-05
Do 1.3E-16
Doc 1.1E-05
100 pA Ap 0.31 0.31 0.31 0.31 0.32 0.32
Bp 0.014 0.029 0.051 0.153 0.298 0.720 Normal
0.009 0.011 0.015 0.033 0.056 0.131 4155C/4156C
compatible
Cp 0.009
Dp 0.002
Ao 0.03 Normal
0.071 4155C/4156C
compatible
Bo 4.7E-16
Boc 3.5E-05
Co 1.3E-14
Coc 9.8E-05
Do 4.7E-16
Doc 3.5E-05