User`s guide
Table Of Contents
- User’s Guide
- 1 Getting Started
- 2 Introduction
- 3 Installation
- 4 Using EasyEXPERT
- 5 Classic Test Definition
- I/V Sweep
- Multi Channel I/V Sweep
- I/V List Sweep
- I/V-t Sampling
- C-V Sweep
- Direct Control
- Function Setup
- Auto Analysis Setup
- Display Setup
- SMU Range Setup Window
- ADC and Integration Time Setup Window
- Advanced Setup Window
- CMU Range Setup Window
- Advanced Setup Window for C-V Sweep
- Switching Matrix Control
- SPGU Control
- SPGU Pulse Setup Window
- Load Z Setup Window
- Pulse Switch Setup Window
- SPGU ALWG Setup Window
- Define ALWG Waveform Window
- 6 Application Test Definition
- 7 Function Details
- I/V Sweep Measurement
- Multi Channel I/V Sweep Measurement
- I/V-t Sampling Measurement
- C-V Sweep Measurement
- SPGU Module
- Sweep Abort Function
- Standby Function
- Bias Hold Function
- Current Offset Cancel
- SMU CMU Unify Unit
- Atto Sense and Switch Unit
- SMU/PG Selector
- SMU Ranging Mode
- SMU Compliance
- SMU Pulse
- SMU Measurement Time
- SMU Filter
- SMU Series Resistor
- Interlock Function
- Auto Power Off Function
- Initial Settings
- 8 Built-in Programming Tool
- 9 If You Have a Problem
- When You Operate B1500A
- When You Perform Measurement
- Measurement Takes More Time than Specified
- Noise Affects the Measured Values
- Voltage Measurement Error is Large
- SMU Oscillates for High-Frequency Device Measurements
- SMU Oscillates for Negative Resistance Measurements
- Large Current Causes High Temperature (Thermal Drift)
- Measurement Damages the Device under Test
- Leaving Connections Damages Devices after Measurement
- Unexpected Sampling Measurement Data is Returned
- MFCMU Causes Unbalance Condition
- Before Shipping to Service Center
- Data Backup and Recovery
- B1500A System Recovery
- Updating EasyEXPERT
- Error Codes
- 10 Application Library and Utilities

9-72 Agilent B1500 User’s Guide, Edition 7
If You Have a Problem
Error Codes
N771 SMU failed VF offset calibration.
N772 SMU failed VF gain calibration.
N773 SMU failed VF gain calibration at 20 V range.
N774 SMU failed VF filter offset calibration.
N775 SMU failed H-SPEED ADC self-calibration.
N776 SMU failed H-SPEED ADC VM offset calibration.
N777 SMU failed H-SPEED ADC VM gain calibration.
N778 SMU failed IF/IM calibration.
N779 SMU failed calibration bus test.
N780 SMU failed IM offset calibration.
N781 SMU failed IM gain calibration.
N782 SMU failed IF offset calibration.
N783 SMU failed IF gain calibration.
N784 SMU failed IDAC filter offset calibration.
N785 SMU failed oscillation detector test.
N786 SMU failed I bias test.
N787 SMU failed common mode rejection test.
N789 SMU failed high voltage detector test.
N790 SMU failed zero voltage detector test.
N791 SMU failed V hold test.
N792 SMU failed V switch test.
N800 CMU failed NULL DC offset adjustment.
N801 CMU failed NULL DC offset measurement.
N802 CMU failed VRD DC offset adjustment.
N803 CMU failed VRD heterodyne offset adjustment.
N804 CMU failed NULL gain/phase adjustment.
N805 CMU failed MODEM offset adjustment.
N806 CMU failed relative Z adjustment.