User`s guide
Table Of Contents
- User’s Guide
- 1 Getting Started
- 2 Introduction
- 3 Installation
- 4 Using EasyEXPERT
- 5 Classic Test Definition
- I/V Sweep
- Multi Channel I/V Sweep
- I/V List Sweep
- I/V-t Sampling
- C-V Sweep
- Direct Control
- Function Setup
- Auto Analysis Setup
- Display Setup
- SMU Range Setup Window
- ADC and Integration Time Setup Window
- Advanced Setup Window
- CMU Range Setup Window
- Advanced Setup Window for C-V Sweep
- Switching Matrix Control
- SPGU Control
- SPGU Pulse Setup Window
- Load Z Setup Window
- Pulse Switch Setup Window
- SPGU ALWG Setup Window
- Define ALWG Waveform Window
- 6 Application Test Definition
- 7 Function Details
- I/V Sweep Measurement
- Multi Channel I/V Sweep Measurement
- I/V-t Sampling Measurement
- C-V Sweep Measurement
- SPGU Module
- Sweep Abort Function
- Standby Function
- Bias Hold Function
- Current Offset Cancel
- SMU CMU Unify Unit
- Atto Sense and Switch Unit
- SMU/PG Selector
- SMU Ranging Mode
- SMU Compliance
- SMU Pulse
- SMU Measurement Time
- SMU Filter
- SMU Series Resistor
- Interlock Function
- Auto Power Off Function
- Initial Settings
- 8 Built-in Programming Tool
- 9 If You Have a Problem
- When You Operate B1500A
- When You Perform Measurement
- Measurement Takes More Time than Specified
- Noise Affects the Measured Values
- Voltage Measurement Error is Large
- SMU Oscillates for High-Frequency Device Measurements
- SMU Oscillates for Negative Resistance Measurements
- Large Current Causes High Temperature (Thermal Drift)
- Measurement Damages the Device under Test
- Leaving Connections Damages Devices after Measurement
- Unexpected Sampling Measurement Data is Returned
- MFCMU Causes Unbalance Condition
- Before Shipping to Service Center
- Data Backup and Recovery
- B1500A System Recovery
- Updating EasyEXPERT
- Error Codes
- 10 Application Library and Utilities

9-46 Agilent B1500 User’s Guide, Edition 7
If You Have a Problem
Error Codes
300109 EasyEXPERT database backup extraction error. See the log file
C:\Documents and Settings\All Users\Application Data\Agilent
Technologie
s, inc\EasyEXPERT\StaDaemon.log if needed. Backup
restoration is
canceled, and the present EasyEXPERT database remains
the same.
300110 Folder delete error. Delete the folder in the following path manually.
Path: A
300111 Eas
yEXPERT database backup restoration error. Database could not be
replaced with the backup.
See the log file C:\Documents and
Settings\All Users\Ap
plication Data\Agilent Technologies,
inc\EasyEXPERT\StaDaemon.log if needed. Source: A, Destin
ation: B
If Source shows the EasyEXPERT database folder name, the database
remains the
same.
If Destination shows the EasyEXPERT database folder name, the
databa
se is broken. Restore the previous database by renaming the
temporary database folder named 1.tmp1A and such.
300112 Application Library update error. Information: A
300113 The specified backup is not complete. Evidence of deletion was
detected. Specify the oth
er backup.
300114 The specified folder is not empty. Specify an empty folder.
300115 Folder deletion was canceled. The folder is left to the following path.
Path: A
300116 Easy
EXPERT database backup extraction was canceled. The ext
racted
files were deleted.
300117 Folder copy was canceled. The copied files
were deleted.
400001 Failed to load inf.dat file. Path: A, Descript
ion: B
400002 Cannot access EasyEXPERT database. Path: A, Descript
ion: B
400003 The specified EasyEXPERT database contains the contents for another
revision. Path: A, De
scription: B
400004 The specified EasyEXPERT database has the incorrect structure. Path:
A, Description: B
4000
05 Failed to load dir file. Path: A, Descriptio
n: B
400006 Cannot access EasyEXPERT database library directory.
Path: A, Descr
iption: B