User`s guide
Table Of Contents
- User’s Guide
- 1 Getting Started
- 2 Introduction
- 3 Installation
- 4 Using EasyEXPERT
- 5 Classic Test Definition
- I/V Sweep
- Multi Channel I/V Sweep
- I/V List Sweep
- I/V-t Sampling
- C-V Sweep
- Direct Control
- Function Setup
- Auto Analysis Setup
- Display Setup
- SMU Range Setup Window
- ADC and Integration Time Setup Window
- Advanced Setup Window
- CMU Range Setup Window
- Advanced Setup Window for C-V Sweep
- Switching Matrix Control
- SPGU Control
- SPGU Pulse Setup Window
- Load Z Setup Window
- Pulse Switch Setup Window
- SPGU ALWG Setup Window
- Define ALWG Waveform Window
- 6 Application Test Definition
- 7 Function Details
- I/V Sweep Measurement
- Multi Channel I/V Sweep Measurement
- I/V-t Sampling Measurement
- C-V Sweep Measurement
- SPGU Module
- Sweep Abort Function
- Standby Function
- Bias Hold Function
- Current Offset Cancel
- SMU CMU Unify Unit
- Atto Sense and Switch Unit
- SMU/PG Selector
- SMU Ranging Mode
- SMU Compliance
- SMU Pulse
- SMU Measurement Time
- SMU Filter
- SMU Series Resistor
- Interlock Function
- Auto Power Off Function
- Initial Settings
- 8 Built-in Programming Tool
- 9 If You Have a Problem
- When You Operate B1500A
- When You Perform Measurement
- Measurement Takes More Time than Specified
- Noise Affects the Measured Values
- Voltage Measurement Error is Large
- SMU Oscillates for High-Frequency Device Measurements
- SMU Oscillates for Negative Resistance Measurements
- Large Current Causes High Temperature (Thermal Drift)
- Measurement Damages the Device under Test
- Leaving Connections Damages Devices after Measurement
- Unexpected Sampling Measurement Data is Returned
- MFCMU Causes Unbalance Condition
- Before Shipping to Service Center
- Data Backup and Recovery
- B1500A System Recovery
- Updating EasyEXPERT
- Error Codes
- 10 Application Library and Utilities

Agilent B1500 User’s Guide, Edition 7 9-45
If You Have a Problem
Error Codes
300021 SDA daemon failed to start SDA service.
path: A, arguments: B, reason: C
3
00031 SDA daemon failed to start SDA shell.
path: A, arguments: B, reason: C
3
00041 SDA daemon failed to start model name inspection process. Path: A,
Arguments:
B, Reason: C
300042 Model name inspection failed. Set VISA interface ID and GPIB address
correctly, or connect the GPIB cable pr
operly. Reason: A
300051 SDA daemon failed to start database recovery process.
Path: A, Argum
ents: B, Reason: C
3
00052 Database recovery failed. Contact Agilent Technologies. Reason: A
300101 Error occurred during inspection for the specified Eas
yEXPERT
database. Path: A
See the log file C:\Documents and Settings\All Users\ Application
Data\Agilent Techn
ologies, inc\EasyEXPERT\StaDaemon.log if
needed.
300102 The specified EasyEXPERT database is broken. Initialize the database
or restore t
he normal database backup. Path: A, Reason: B
300103 EasyEXPERT database backup file (.xdb) is broken. Cannot restore this
backup. Path:
A
300104 Insufficient free space of HDD. Drive: A Present Free Space: B bytes
Required
Free Space: C bytes
Retry the operation after increasing free space. Free space can be
increased by delet
ing unnecessary files, compressing folders, and so on.
300105 EasyEXPERT database is not in the specified drive A. Specify a folder
on the
drive B where the EasyEXPERT database exists.
300106 The specified backup contains the EasyEXPERT database contents for
another revisio
n. Specify the other backup. Contents: A
300107 The specified backup does not contain the file or folder needed to
rest
ore the database. Specify the other backup. Contents: A
300108 The specified backup contains the database that is created by the
EasyEXPER
T revision A. It cannot be supported by the present
revision. Specify the other backup.