User`s guide
Table Of Contents
- User’s Guide
- 1 Getting Started
- 2 Introduction
- 3 Installation
- 4 Using EasyEXPERT
- 5 Classic Test Definition
- I/V Sweep
- Multi Channel I/V Sweep
- I/V List Sweep
- I/V-t Sampling
- C-V Sweep
- Direct Control
- Function Setup
- Auto Analysis Setup
- Display Setup
- SMU Range Setup Window
- ADC and Integration Time Setup Window
- Advanced Setup Window
- CMU Range Setup Window
- Advanced Setup Window for C-V Sweep
- Switching Matrix Control
- SPGU Control
- SPGU Pulse Setup Window
- Load Z Setup Window
- Pulse Switch Setup Window
- SPGU ALWG Setup Window
- Define ALWG Waveform Window
- 6 Application Test Definition
- 7 Function Details
- I/V Sweep Measurement
- Multi Channel I/V Sweep Measurement
- I/V-t Sampling Measurement
- C-V Sweep Measurement
- SPGU Module
- Sweep Abort Function
- Standby Function
- Bias Hold Function
- Current Offset Cancel
- SMU CMU Unify Unit
- Atto Sense and Switch Unit
- SMU/PG Selector
- SMU Ranging Mode
- SMU Compliance
- SMU Pulse
- SMU Measurement Time
- SMU Filter
- SMU Series Resistor
- Interlock Function
- Auto Power Off Function
- Initial Settings
- 8 Built-in Programming Tool
- 9 If You Have a Problem
- When You Operate B1500A
- When You Perform Measurement
- Measurement Takes More Time than Specified
- Noise Affects the Measured Values
- Voltage Measurement Error is Large
- SMU Oscillates for High-Frequency Device Measurements
- SMU Oscillates for Negative Resistance Measurements
- Large Current Causes High Temperature (Thermal Drift)
- Measurement Damages the Device under Test
- Leaving Connections Damages Devices after Measurement
- Unexpected Sampling Measurement Data is Returned
- MFCMU Causes Unbalance Condition
- Before Shipping to Service Center
- Data Backup and Recovery
- B1500A System Recovery
- Updating EasyEXPERT
- Error Codes
- 10 Application Library and Utilities

9-44 Agilent B1500 User’s Guide, Edition 7
If You Have a Problem
Error Codes
170001 Archive process failed. Reason: A
171001 Data compression failed. Program error. Contact Agilent Technologies.
171002 Specify a correct file for the import. Specified file i
s either unsupported
or corrupt.
171003 File I/O failed during compressed data export. Could not access
destination
file. Specified file is either unsupported or corrupt. Specify
a correct file for
the export.
171004 Compression process or decompression process failed. Specified file is
either unsup
ported or corrupt. Specify a correct file for the export or
import. It may als
o be a program error.
200001 Select from the candidates. Specify the value from the choi
ces for this
field.
200002 Input a numeric value. The value must be numeric. Enter a numeric
value.
200003 N
umber of grid data elements must be A or less.
2
00004 Data paste failed. Data format is unsupported or incorrect.
200005 Data paste failed. Data of size A×B cannot be past
ed to position C,D. It
must be pasted to a range of E×F.
201001 Failed to load image data. File A may not be an i
mage file.
202001 The name A already exists.
300001 SDA daemo
n is already running.
300002 SDA daemon configuration file is corrupt. Check the file
C:\Progra
m Files\Agilent\B1500\EasyEXPERT\Daemon\StaDaemon.e
xe.config.
3
00003 Specify a correct folder for the EasyEXPERT databas
e. Specified
folder not found.
300004 Moving of EasyEXPERT database failed. Refer to the detail message,
and retry after taking necessary measures.
300011 SDA daemon failed to start FLEX command service.
path: A, arguments: B, reason: C
3
00012 FLEX command service was stopped by SDA daemon. After closing
Agilent
Connection Expert, launch Start EasyEXPERT or restart
B1500A.