User`s guide
Table Of Contents
- User’s Guide
- 1 Getting Started
- 2 Introduction
- 3 Installation
- 4 Using EasyEXPERT
- 5 Classic Test Definition
- I/V Sweep
- Multi Channel I/V Sweep
- I/V List Sweep
- I/V-t Sampling
- C-V Sweep
- Direct Control
- Function Setup
- Auto Analysis Setup
- Display Setup
- SMU Range Setup Window
- ADC and Integration Time Setup Window
- Advanced Setup Window
- CMU Range Setup Window
- Advanced Setup Window for C-V Sweep
- Switching Matrix Control
- SPGU Control
- SPGU Pulse Setup Window
- Load Z Setup Window
- Pulse Switch Setup Window
- SPGU ALWG Setup Window
- Define ALWG Waveform Window
- 6 Application Test Definition
- 7 Function Details
- I/V Sweep Measurement
- Multi Channel I/V Sweep Measurement
- I/V-t Sampling Measurement
- C-V Sweep Measurement
- SPGU Module
- Sweep Abort Function
- Standby Function
- Bias Hold Function
- Current Offset Cancel
- SMU CMU Unify Unit
- Atto Sense and Switch Unit
- SMU/PG Selector
- SMU Ranging Mode
- SMU Compliance
- SMU Pulse
- SMU Measurement Time
- SMU Filter
- SMU Series Resistor
- Interlock Function
- Auto Power Off Function
- Initial Settings
- 8 Built-in Programming Tool
- 9 If You Have a Problem
- When You Operate B1500A
- When You Perform Measurement
- Measurement Takes More Time than Specified
- Noise Affects the Measured Values
- Voltage Measurement Error is Large
- SMU Oscillates for High-Frequency Device Measurements
- SMU Oscillates for Negative Resistance Measurements
- Large Current Causes High Temperature (Thermal Drift)
- Measurement Damages the Device under Test
- Leaving Connections Damages Devices after Measurement
- Unexpected Sampling Measurement Data is Returned
- MFCMU Causes Unbalance Condition
- Before Shipping to Service Center
- Data Backup and Recovery
- B1500A System Recovery
- Updating EasyEXPERT
- Error Codes
- 10 Application Library and Utilities

Agilent B1500 User’s Guide, Edition 7 9-41
If You Have a Problem
Error Codes
130001 Transport function error occurred.
130002 A target package was not found. Cannot import data because of invalid
file format or corru
pted file. Specify correct file.
130003 The package is unusable because it includes incor
rect data. Cannot
import data because of invalid file format or corrupted file. Specify
correct file.
130004 Package data is insufficient for this process. Cannot import data
because of in
valid file format or corrupted file. Specify correct file.
130005 File I/O error. Cannot find or access the package file.
130011 Data import failed. Data may be incompatible or corrupt. Data: A
131001 Conversion function error occurred.
131002 Invalid style sheet. Cannot export data (to CSV or XMLSS) because of
in
valid file form
at or corrupted file. Specify correct file.
131003 Invalid XML document. Restart Agilent B1500A. If the problem still
occurs, contact your neares
t Agilent Technologies Service Center.
131004 Conversion process failed. Cannot export data (to CSV or XMLSS)
because of in
valid file format or corrupted file. Specify correct file.
131005 File I/O error. Cannot access the target file.
132001 Command interface error occurred.
132002 The process failed to execute the specified external command. Confirm
th
at the file is in
the system path, and specify the correct file name.
Otherwise the file might have a problem.
133001 GPIB interface error occurred.
133002 Internal error occurred during GPIB operation. GPIB interface might be
defective.
133003 The GPI
B operation failed to complete within the specified timeout
period. Set th
e correct timeout value. GPIB interface might be
defective.
133004 The sp
ecified expression does not match any devi
ce, or the GPIB
resource was not found. Set GPIB address properly. GPIB interface
might be
defective.
133005 The specified GPIB resources are invalid. Set GPIB address properly.