User`s guide
Table Of Contents
- User’s Guide
- 1 Getting Started
- 2 Introduction
- 3 Installation
- 4 Using EasyEXPERT
- 5 Classic Test Definition
- I/V Sweep
- Multi Channel I/V Sweep
- I/V List Sweep
- I/V-t Sampling
- C-V Sweep
- Direct Control
- Function Setup
- Auto Analysis Setup
- Display Setup
- SMU Range Setup Window
- ADC and Integration Time Setup Window
- Advanced Setup Window
- CMU Range Setup Window
- Advanced Setup Window for C-V Sweep
- Switching Matrix Control
- SPGU Control
- SPGU Pulse Setup Window
- Load Z Setup Window
- Pulse Switch Setup Window
- SPGU ALWG Setup Window
- Define ALWG Waveform Window
- 6 Application Test Definition
- 7 Function Details
- I/V Sweep Measurement
- Multi Channel I/V Sweep Measurement
- I/V-t Sampling Measurement
- C-V Sweep Measurement
- SPGU Module
- Sweep Abort Function
- Standby Function
- Bias Hold Function
- Current Offset Cancel
- SMU CMU Unify Unit
- Atto Sense and Switch Unit
- SMU/PG Selector
- SMU Ranging Mode
- SMU Compliance
- SMU Pulse
- SMU Measurement Time
- SMU Filter
- SMU Series Resistor
- Interlock Function
- Auto Power Off Function
- Initial Settings
- 8 Built-in Programming Tool
- 9 If You Have a Problem
- When You Operate B1500A
- When You Perform Measurement
- Measurement Takes More Time than Specified
- Noise Affects the Measured Values
- Voltage Measurement Error is Large
- SMU Oscillates for High-Frequency Device Measurements
- SMU Oscillates for Negative Resistance Measurements
- Large Current Causes High Temperature (Thermal Drift)
- Measurement Damages the Device under Test
- Leaving Connections Damages Devices after Measurement
- Unexpected Sampling Measurement Data is Returned
- MFCMU Causes Unbalance Condition
- Before Shipping to Service Center
- Data Backup and Recovery
- B1500A System Recovery
- Updating EasyEXPERT
- Error Codes
- 10 Application Library and Utilities

9-40 Agilent B1500 User’s Guide, Edition 7
If You Have a Problem
Error Codes
122004 Invalid expression is specified for function argument. Function: A,
Argument: B
Correct the expression defined for the argument B of the functi
on A.
Click the Detail button for more information.
122005 Invalid type of data is specified as function argument. Correct the data
type of the variable used
for the argument. Or change the variable that
is the same data type as the argument.
122006 Incorrect data is specified as function argument.
122007 Specified argument is out of range. Correct the value of the argument.
The value m
ust be within its allowable range.
122008 Invalid character is used for system sym
bol. System symbol: A, Invalid
character: B
122009 Invalid character is used for user defined symbol. User defined symbol:
A, Invalid
character: B
Use the characters available for the user defined symbol.
122010 Missing operator. Index: A
Correct the expression. Put the operator on the correct place.
122011 Missing operand. Index: A
Correct the expression. Number of operands must be one for the
mo
nomial
operators, and two for the binomial operators.
122012 Operand Type Mismatch. Operator: A
Correct the expression. The type of operands used in the expression
must be th
e same.
122013 Undefined Symbol is used. Symbol: A
Correct the expression. Symbols must be defined before using them in
the expression.
1
22014 Function failed to call. Function: A
Failed to call the function A. For more info
rmation, click the Detail
button.
122015 Number of vector data elements must be A or less.
1
23000 Only literal value can be specified here. Invalid character is entered in
the Variable Insp