User`s guide
Table Of Contents
- User’s Guide
- 1 Getting Started
- 2 Introduction
- 3 Installation
- 4 Using EasyEXPERT
- 5 Classic Test Definition
- I/V Sweep
- Multi Channel I/V Sweep
- I/V List Sweep
- I/V-t Sampling
- C-V Sweep
- Direct Control
- Function Setup
- Auto Analysis Setup
- Display Setup
- SMU Range Setup Window
- ADC and Integration Time Setup Window
- Advanced Setup Window
- CMU Range Setup Window
- Advanced Setup Window for C-V Sweep
- Switching Matrix Control
- SPGU Control
- SPGU Pulse Setup Window
- Load Z Setup Window
- Pulse Switch Setup Window
- SPGU ALWG Setup Window
- Define ALWG Waveform Window
- 6 Application Test Definition
- 7 Function Details
- I/V Sweep Measurement
- Multi Channel I/V Sweep Measurement
- I/V-t Sampling Measurement
- C-V Sweep Measurement
- SPGU Module
- Sweep Abort Function
- Standby Function
- Bias Hold Function
- Current Offset Cancel
- SMU CMU Unify Unit
- Atto Sense and Switch Unit
- SMU/PG Selector
- SMU Ranging Mode
- SMU Compliance
- SMU Pulse
- SMU Measurement Time
- SMU Filter
- SMU Series Resistor
- Interlock Function
- Auto Power Off Function
- Initial Settings
- 8 Built-in Programming Tool
- 9 If You Have a Problem
- When You Operate B1500A
- When You Perform Measurement
- Measurement Takes More Time than Specified
- Noise Affects the Measured Values
- Voltage Measurement Error is Large
- SMU Oscillates for High-Frequency Device Measurements
- SMU Oscillates for Negative Resistance Measurements
- Large Current Causes High Temperature (Thermal Drift)
- Measurement Damages the Device under Test
- Leaving Connections Damages Devices after Measurement
- Unexpected Sampling Measurement Data is Returned
- MFCMU Causes Unbalance Condition
- Before Shipping to Service Center
- Data Backup and Recovery
- B1500A System Recovery
- Updating EasyEXPERT
- Error Codes
- 10 Application Library and Utilities

Agilent B1500 User’s Guide, Edition 7 5- 65
Classic Test Definition
Define ALWG Waveform Window
Delete Deletes the column data highlighted in the Sequence
Editor area.
Move Moves the highlighted column to the left or the right.
Repeat Count Opens the Repeat Count dialog box used to set the repeat
count.
Seque
nce Editor Specifies the output channel, the output
pattern, the repeat count of the pattern, and
the output sequence of patterns. These setup information create the arbitrary linear
waveform data.
Column No. Number for specifying the output sequence. The pattern will be
output in
the order of this number.
Repeat Count Output repeat count for the pattern specified by the channel
field (e.g right field of
the label “SPGU1:HV”). The repeat
count must be entered in this field.
channel
(e.g SPGU1:HV) Output channel and its output pattern. The channel
is specified
by the header (e.g SPGU1:HV) of this row. The pattern data
must be specified by this entry field. A pre-defined pattern can
be selected from the drop down menu in this field. The right
button opens the Waveform Pattern Editor.
This area provides the following buttons.
Insert Column Adds a column.
Delete Column Deletes the highlighted column.
To Left Move the highlighted column to the left.
To Right Move the highlighted column to the right.
This area also provides the following functions in the menu displayed by
rig
ht-clicking
this area.
Cancel Closes the menu.
Insert Column Adds a column.
Delete Column Deletes the highlighted column.
Move Column Moves the highlighted column to the left or the right.
Repeat Count Opens the Repeat Count dialog box us
ed to set the repeat cou
nt.
Edit Opens the Waveform Pattern Editor with the specified pattern
data (P
attern) or the specified column data (Column).