User`s guide
Table Of Contents
- User’s Guide
- 1 Getting Started
- 2 Introduction
- 3 Installation
- 4 Using EasyEXPERT
- 5 Classic Test Definition
- I/V Sweep
- Multi Channel I/V Sweep
- I/V List Sweep
- I/V-t Sampling
- C-V Sweep
- Direct Control
- Function Setup
- Auto Analysis Setup
- Display Setup
- SMU Range Setup Window
- ADC and Integration Time Setup Window
- Advanced Setup Window
- CMU Range Setup Window
- Advanced Setup Window for C-V Sweep
- Switching Matrix Control
- SPGU Control
- SPGU Pulse Setup Window
- Load Z Setup Window
- Pulse Switch Setup Window
- SPGU ALWG Setup Window
- Define ALWG Waveform Window
- 6 Application Test Definition
- 7 Function Details
- I/V Sweep Measurement
- Multi Channel I/V Sweep Measurement
- I/V-t Sampling Measurement
- C-V Sweep Measurement
- SPGU Module
- Sweep Abort Function
- Standby Function
- Bias Hold Function
- Current Offset Cancel
- SMU CMU Unify Unit
- Atto Sense and Switch Unit
- SMU/PG Selector
- SMU Ranging Mode
- SMU Compliance
- SMU Pulse
- SMU Measurement Time
- SMU Filter
- SMU Series Resistor
- Interlock Function
- Auto Power Off Function
- Initial Settings
- 8 Built-in Programming Tool
- 9 If You Have a Problem
- When You Operate B1500A
- When You Perform Measurement
- Measurement Takes More Time than Specified
- Noise Affects the Measured Values
- Voltage Measurement Error is Large
- SMU Oscillates for High-Frequency Device Measurements
- SMU Oscillates for Negative Resistance Measurements
- Large Current Causes High Temperature (Thermal Drift)
- Measurement Damages the Device under Test
- Leaving Connections Damages Devices after Measurement
- Unexpected Sampling Measurement Data is Returned
- MFCMU Causes Unbalance Condition
- Before Shipping to Service Center
- Data Backup and Recovery
- B1500A System Recovery
- Updating EasyEXPERT
- Error Codes
- 10 Application Library and Utilities

5- 64 Agilent B1500 User’s Guide, Edition 7
Classic Test Definition
Define ALWG Waveform Window
Define ALWG Waveform Window
This window is opened by clicking the start button in the waveform data entry field
or the ALWG Source field on the SPGU ALWG Setup window, and is used to create
the arbitrary linear waveform data which is defined by the pattern data and the
sequence data.
File menu Provides the following five functions.
Export ALWaveform... Exports the waveform data.
Import ALWaveform... Imports the specified waveform data.
Export Pattern... Exports the pattern highlighted in the Patterns display
area.
Import Patterns... Imports the specified pattern data.
Close Closes the Define ALWG Waveform window.
Pattern menu Provides the following six functions.
New This is for creating a new pattern. Opens the New Pattern
dialog bo
x. Entering a new name opens Waveform
Pattern Editor (p. 5-67).
Edit Opens the Waveform Pattern Editor with the pattern
highligh
ted in the Pattern display area.
Cut Cuts the pattern highlighted in the Pattern display area
and stores it
on the Clipboard.
Copy Copies the pattern highlighted in the Pattern display area
to the Clip
board.
Paste Pastes the pattern stored on the Clipboard.
Rename Renames the pattern highlighted in the Pattern display
area.
Column menu Provides the following five functions.
Edit Opens the Waveform Pattern Editor with the column data
highlighted
in the Sequence Editor area.
Insert Adds a column.