- 1 Getting Started
- 2 Introduction
- 3 Installation
- 4 Using EasyEXPERT
- 5 Classic Test Definition
- I/V Sweep
- Multi Channel I/V Sweep
- I/V List Sweep
- I/V-t Sampling
- C-V Sweep
- Direct Control
- Function Setup
- Auto Analysis Setup
- Display Setup
- SMU Range Setup Window
- ADC and Integration Time Setup Window
- Advanced Setup Window
- CMU Range Setup Window
- Advanced Setup Window for C-V Sweep
- Switching Matrix Control
- SPGU Control
- SPGU Pulse Setup Window
- Load Z Setup Window
- Pulse Switch Setup Window
- SPGU ALWG Setup Window
- Define ALWG Waveform Window
- 6 Application Test Definition
- 7 Function Details
- I/V Sweep Measurement
- Multi Channel I/V Sweep Measurement
- I/V-t Sampling Measurement
- C-V Sweep Measurement
- SPGU Module
- Sweep Abort Function
- Standby Function
- Bias Hold Function
- Current Offset Cancel
- SMU CMU Unify Unit
- Atto Sense and Switch Unit
- SMU/PG Selector
- SMU Ranging Mode
- SMU Compliance
- SMU Pulse
- SMU Measurement Time
- SMU Filter
- SMU Series Resistor
- Interlock Function
- Auto Power Off Function
- Initial Settings
- 8 Built-in Programming Tool
- 9 If You Have a Problem
- When You Operate B1500A
- When You Perform Measurement
- Measurement Takes More Time than Specified
- Noise Affects the Measured Values
- Voltage Measurement Error is Large
- SMU Oscillates for High-Frequency Device Measurements
- SMU Oscillates for Negative Resistance Measurements
- Large Current Causes High Temperature (Thermal Drift)
- Measurement Damages the Device under Test
- Leaving Connections Damages Devices after Measurement
- Unexpected Sampling Measurement Data is Returned
- MFCMU Causes Unbalance Condition
- Before Shipping to Service Center
- Data Backup and Recovery
- B1500A System Recovery
- Updating EasyEXPERT
- Error Codes
- 10 Application Library and Utilities

4- 72 Agilent B1500 User’s Guide, Edition 7
Using EasyEXPERT
Data Display
Table 4-7 Mouse/Touch Panel Operations on Data Display Window
Location Operation Description
X-Y Graph clicking on the left
Y axis
Activates th
e Y1 data.
clicking on the
right Y axis
Activa
tes the data of the right Y axis, or changes the active data
if it is already active.
clicking on a plot Moves the marker to the position of the mouse pointer if the
marker is disp
layed on the graph.
clicking on a cursor Specifies the active cursor if multiple cursors are displayed.
dragging a cursor Moves the cursor.
clicking on a line Specifies the active line if multiple lines are displayed.
clicking on a text Selects the text.
Clicking with pressing the Shift key on the keyboard selects
multiple texts.
dra
gging a text Moves the text.
clicking on a
pointer
Sel
ects the pointer.
Clicking with pressing the Shift key on the keyboard selects
multiple poin
ters.
clicking on a
descriptio
n of
pointer
Selects the description of pointer.
Clicking with pressing the Shift key on the key board selects
multiple des
criptions of pointers.
dragging a
descriptio
n of
pointer
Moves the description of pointer.
rotating the mouse
wheel
Moves the marker if the marker is displayed on the graph,
moves
the pointer if the pointer is selected, or adjusts the slope
of the gradient line if it is in the slope adjustment mode (Line >