User`s guide
Table Of Contents
- User’s Guide
- 1 Getting Started
- 2 Introduction
- 3 Installation
- 4 Using EasyEXPERT
- 5 Classic Test Definition
- I/V Sweep
- Multi Channel I/V Sweep
- I/V List Sweep
- I/V-t Sampling
- C-V Sweep
- Direct Control
- Function Setup
- Auto Analysis Setup
- Display Setup
- SMU Range Setup Window
- ADC and Integration Time Setup Window
- Advanced Setup Window
- CMU Range Setup Window
- Advanced Setup Window for C-V Sweep
- Switching Matrix Control
- SPGU Control
- SPGU Pulse Setup Window
- Load Z Setup Window
- Pulse Switch Setup Window
- SPGU ALWG Setup Window
- Define ALWG Waveform Window
- 6 Application Test Definition
- 7 Function Details
- I/V Sweep Measurement
- Multi Channel I/V Sweep Measurement
- I/V-t Sampling Measurement
- C-V Sweep Measurement
- SPGU Module
- Sweep Abort Function
- Standby Function
- Bias Hold Function
- Current Offset Cancel
- SMU CMU Unify Unit
- Atto Sense and Switch Unit
- SMU/PG Selector
- SMU Ranging Mode
- SMU Compliance
- SMU Pulse
- SMU Measurement Time
- SMU Filter
- SMU Series Resistor
- Interlock Function
- Auto Power Off Function
- Initial Settings
- 8 Built-in Programming Tool
- 9 If You Have a Problem
- When You Operate B1500A
- When You Perform Measurement
- Measurement Takes More Time than Specified
- Noise Affects the Measured Values
- Voltage Measurement Error is Large
- SMU Oscillates for High-Frequency Device Measurements
- SMU Oscillates for Negative Resistance Measurements
- Large Current Causes High Temperature (Thermal Drift)
- Measurement Damages the Device under Test
- Leaving Connections Damages Devices after Measurement
- Unexpected Sampling Measurement Data is Returned
- MFCMU Causes Unbalance Condition
- Before Shipping to Service Center
- Data Backup and Recovery
- B1500A System Recovery
- Updating EasyEXPERT
- Error Codes
- 10 Application Library and Utilities

Agilent B1500 User’s Guide, Edition 7 4- 15
Using EasyEXPERT
Main Screen
Standby ON This indicator is located at the bottom of the EasyEXPERT main screen and is lit
while the standby function is enabled (standby mode is ON).
Multi Display ON This indicator is located at the bottom of the EasyEXPERT main screen and is lit
while the Multi Disp
lay function is enabled.
workspace name Field below the Results button shows the present workspace name.
Results This button provides the following functions. The list area s
hows the test records.
The up or down arrow button is used to expand or reduce the list area.
Cancel Closes the menu.
Select All Selects all records.
Unselect All Unselects all records.
Display Data Opens the “Data Display (page 4-51)” and displays the
test result data of the selected record. Up to 15
w
indows can be
opened by this function.
Recall Recalls the test setup of the selected record.
Filter Provides the following four functions.
Show Deleted Data Check this function to see the test records of both
S
ave-group
and Delete-group. To set the data group,
see “Flag and Remarks” on page 4-17. See also “Test
Result Editor (page 4-21)”.
Filter... Opens the “Test Results Data Filter (page 4-22)” dialog
box. You can filter the test records in the list area.
Expand Application Test
Results Check th
is function to see all test records created
by the
test setups defined in an application test.
If a test record is exported when this function is not
checked, the expo
rted file will contain all records
created by the test setups defined in an application test.
However, if the test record is exported by the Export
As Text File function, the exported file will contain
only the test record of the application test.