User`s guide
Table Of Contents
- User’s Guide
- 1 Getting Started
- 2 Introduction
- 3 Installation
- 4 Using EasyEXPERT
- 5 Classic Test Definition
- I/V Sweep
- Multi Channel I/V Sweep
- I/V List Sweep
- I/V-t Sampling
- C-V Sweep
- Direct Control
- Function Setup
- Auto Analysis Setup
- Display Setup
- SMU Range Setup Window
- ADC and Integration Time Setup Window
- Advanced Setup Window
- CMU Range Setup Window
- Advanced Setup Window for C-V Sweep
- Switching Matrix Control
- SPGU Control
- SPGU Pulse Setup Window
- Load Z Setup Window
- Pulse Switch Setup Window
- SPGU ALWG Setup Window
- Define ALWG Waveform Window
- 6 Application Test Definition
- 7 Function Details
- I/V Sweep Measurement
- Multi Channel I/V Sweep Measurement
- I/V-t Sampling Measurement
- C-V Sweep Measurement
- SPGU Module
- Sweep Abort Function
- Standby Function
- Bias Hold Function
- Current Offset Cancel
- SMU CMU Unify Unit
- Atto Sense and Switch Unit
- SMU/PG Selector
- SMU Ranging Mode
- SMU Compliance
- SMU Pulse
- SMU Measurement Time
- SMU Filter
- SMU Series Resistor
- Interlock Function
- Auto Power Off Function
- Initial Settings
- 8 Built-in Programming Tool
- 9 If You Have a Problem
- When You Operate B1500A
- When You Perform Measurement
- Measurement Takes More Time than Specified
- Noise Affects the Measured Values
- Voltage Measurement Error is Large
- SMU Oscillates for High-Frequency Device Measurements
- SMU Oscillates for Negative Resistance Measurements
- Large Current Causes High Temperature (Thermal Drift)
- Measurement Damages the Device under Test
- Leaving Connections Damages Devices after Measurement
- Unexpected Sampling Measurement Data is Returned
- MFCMU Causes Unbalance Condition
- Before Shipping to Service Center
- Data Backup and Recovery
- B1500A System Recovery
- Updating EasyEXPERT
- Error Codes
- 10 Application Library and Utilities

Agilent B1500 User’s Guide, Edition 7 4- 11
Using EasyEXPERT
Main Screen
Main Screen GUI
File menu Provides the following four functions.
Import Test Setup... Opens a dialog box used to specify a test setup to
import.
Export T
est Setup... Opens a dialog box used to specify a destination
file for expor
ting the present test setup.
Close Workspace Closes the work space and returns to the workspace
configurator.
Exit
Exits the EasyEXPERT software.
Data Display menu Provides the following three functions.
Show Data Display Opens “Data Display (page 4-51)” used to display
the test result data.
Manage Data Display... Opens “Data Display Manager (page 4-19)” used to
control the appearances of the Data Display
windows.
Defau
lt Data Display
Properties... Opens “
Data Display Properties (page 4-20)” used
to set the default setting of the Data Display
window.
Help menu Pro
vides the following three functions.
About This Instrument... Opens the Configuration window.
About This Test... Opens the test description dialog box.
Agilent EasyEXPERT Help Opens the EasyEXPERT help window.
Application Test This tab selects the application test mode of EasyEXPERT. For details of the
graphical us
er interface in this mode, see “Application Test” on page 4-27.
Classic Test This tab selects the classic test mode of the EasyEXPERT. For details of the
g
raphical us
er interface in this mode, see “Classic Test Definition” on page 5-1.
Quick Test This tab selects the quick test mode of the Eas
yEXPERT. For de
tails of the graphical
user interface in this mode, see “Quick Test” on page 4-29.