User`s guide
Table Of Contents
- User’s Guide
- 1 Getting Started
- 2 Introduction
- 3 Installation
- 4 Using EasyEXPERT
- 5 Classic Test Definition
- I/V Sweep
- Multi Channel I/V Sweep
- I/V List Sweep
- I/V-t Sampling
- C-V Sweep
- Direct Control
- Function Setup
- Auto Analysis Setup
- Display Setup
- SMU Range Setup Window
- ADC and Integration Time Setup Window
- Advanced Setup Window
- CMU Range Setup Window
- Advanced Setup Window for C-V Sweep
- Switching Matrix Control
- SPGU Control
- SPGU Pulse Setup Window
- Load Z Setup Window
- Pulse Switch Setup Window
- SPGU ALWG Setup Window
- Define ALWG Waveform Window
- 6 Application Test Definition
- 7 Function Details
- I/V Sweep Measurement
- Multi Channel I/V Sweep Measurement
- I/V-t Sampling Measurement
- C-V Sweep Measurement
- SPGU Module
- Sweep Abort Function
- Standby Function
- Bias Hold Function
- Current Offset Cancel
- SMU CMU Unify Unit
- Atto Sense and Switch Unit
- SMU/PG Selector
- SMU Ranging Mode
- SMU Compliance
- SMU Pulse
- SMU Measurement Time
- SMU Filter
- SMU Series Resistor
- Interlock Function
- Auto Power Off Function
- Initial Settings
- 8 Built-in Programming Tool
- 9 If You Have a Problem
- When You Operate B1500A
- When You Perform Measurement
- Measurement Takes More Time than Specified
- Noise Affects the Measured Values
- Voltage Measurement Error is Large
- SMU Oscillates for High-Frequency Device Measurements
- SMU Oscillates for Negative Resistance Measurements
- Large Current Causes High Temperature (Thermal Drift)
- Measurement Damages the Device under Test
- Leaving Connections Damages Devices after Measurement
- Unexpected Sampling Measurement Data is Returned
- MFCMU Causes Unbalance Condition
- Before Shipping to Service Center
- Data Backup and Recovery
- B1500A System Recovery
- Updating EasyEXPERT
- Error Codes
- 10 Application Library and Utilities

3- 54 Agilent B1500 User’s Guide, Edition 7
Installation
Capacitance Compensation When Using Switching Matrix
Table 3-11 Template Compensation Data Files for B2200A/B2201A
File name
a
a. <path>: \Program Files\Agilent\B1500\EasyEXPERT\B220xA\ccdata
Measurement environment that templ
ate targets
Switch
module
Cable
b
b. Model number of the cable connected between the switch module and the DUT interface.
DUT
interface
c
c. Agilent B2220A probe card interface or Agilent 16495F/G connector plate.
Coefficients to
be modified
<path>\b2210a\pcif\triax\3m.data B2210A 16494A-002 B2220A C3H and C3L
<path>\b2210a\pcif\triax\4m.data 16494A-005
<path>\b2210a\pcif\kelvin\3m.data 16494C-002
<path>\b2210a\pcif\kelvin\4m.data 16494C-005
<path>\b2210a\cable\triax\1_5m.data 16494A-001 16495F/G C2H, C2L,
C3H
, and C3L
<path
>\b2210a\cable\triax\3m.data 16494A-002
<path>\b2210a\cable\triax\4m.data 16494A-005
<path>\b2210a\cable\kelvin\1_5m.data 16494B-001
<path>\b2210a\cable\kelvin\3m.data 16494B-002
<path>\b2210a\cable\kelvin\4m.data 16494C-005
<path>\b2211a\pcif\triax\3m.data B2211A 16494A-002 B2220A C3H and C3L
<path>\b2211a\pcif\triax\4m.data 16494A-005
<path>\b2211a\pcif\kelvin\3m.data 16494C-002
<path>\b2211a\pcif\kelvin\4m.data 16494C-005
<path>\b2211a\cable\triax\1_5m.data 16494A-001 16495F/G C2H, C2L,
C3H
, and C3L
<path
>\b2211a\cable\triax\3m.data 16494A-002
<path>\b2211a\cable\triax\4m.data 16494A-005
<path>\b2211a\cable\kelvin\1_5m.data 16494B-001
<path>\b2211a\cable\kelvin\3m.data 16494B-002
<path>\b2211a\cable\kelvin\4m.data 16494C-005