User`s guide
Table Of Contents
- User’s Guide
- 1 Getting Started
- 2 Introduction
- 3 Installation
- 4 Using EasyEXPERT
- 5 Classic Test Definition
- I/V Sweep
- Multi Channel I/V Sweep
- I/V List Sweep
- I/V-t Sampling
- C-V Sweep
- Direct Control
- Function Setup
- Auto Analysis Setup
- Display Setup
- SMU Range Setup Window
- ADC and Integration Time Setup Window
- Advanced Setup Window
- CMU Range Setup Window
- Advanced Setup Window for C-V Sweep
- Switching Matrix Control
- SPGU Control
- SPGU Pulse Setup Window
- Load Z Setup Window
- Pulse Switch Setup Window
- SPGU ALWG Setup Window
- Define ALWG Waveform Window
- 6 Application Test Definition
- 7 Function Details
- I/V Sweep Measurement
- Multi Channel I/V Sweep Measurement
- I/V-t Sampling Measurement
- C-V Sweep Measurement
- SPGU Module
- Sweep Abort Function
- Standby Function
- Bias Hold Function
- Current Offset Cancel
- SMU CMU Unify Unit
- Atto Sense and Switch Unit
- SMU/PG Selector
- SMU Ranging Mode
- SMU Compliance
- SMU Pulse
- SMU Measurement Time
- SMU Filter
- SMU Series Resistor
- Interlock Function
- Auto Power Off Function
- Initial Settings
- 8 Built-in Programming Tool
- 9 If You Have a Problem
- When You Operate B1500A
- When You Perform Measurement
- Measurement Takes More Time than Specified
- Noise Affects the Measured Values
- Voltage Measurement Error is Large
- SMU Oscillates for High-Frequency Device Measurements
- SMU Oscillates for Negative Resistance Measurements
- Large Current Causes High Temperature (Thermal Drift)
- Measurement Damages the Device under Test
- Leaving Connections Damages Devices after Measurement
- Unexpected Sampling Measurement Data is Returned
- MFCMU Causes Unbalance Condition
- Before Shipping to Service Center
- Data Backup and Recovery
- B1500A System Recovery
- Updating EasyEXPERT
- Error Codes
- 10 Application Library and Utilities

2- 78 Agilent B1500 User’s Guide, Edition 7
Introduction
Accessories and Options
E5288A Atto Sense and Switch Unit (ASU)
E5288A-001 Add triaxial and D-sub cables, 1.5 m
E5288A-002 Add triaxial and D-sub cables, 3 m
N1253A Accessories for Digital I/O
N1253A-100 Digital I/O T-cable
N1253A-200 Digital I/O BNC Box
N1254A Accessories
N1254A-100 GNDU to Kelvin Adapter
N1254A-107 Triax(m)-Triax(f) Adapter
N1254A-108 ASU Magnetic Stand
N1300A CMU cable
N1300A-001 1.5 m length
N1300A-002 3 m length
N1301A Accessories for CMU
N1301A-100 SMU CMU Unify Unit (SCUU)
N1301A-102 SCUU cable, 3 m
N1301A-110 SCUU magnetic stand
N1301A-200 Guard Switch Unit (GSWU)
N1301A-201 GSWU cable, 1.5 m
N1301A-202 GSWU cable, 3 m
16435A Interlock cable adapter (B1500 type to BNC)
16440A SMU/Pulse Generator selector
16440A-001 Control cable, 1.5 m
16440A-002 Control cable, 3.0 m
16440A-003 Control cable, 40 cm for second selector
Model
Nu
mber
Optio