Technical data
5 Pulse Configuration Commands
60 U2761A Programmer’s Reference
[SOURce:]FUNCtion:PULSe:WIDTh
Syntax
[SOURce:]FUNCtion:PULSe:WIDTh <seconds>
This command sets the pulse width in seconds. The pulse width
represents the time from the 50% threshold of the pulse rising edge to the
50% threshold of the next falling edge.
[SOURce:]FUNCtion:PULSe:WIDTh?
This query returns the pulse width in seconds.
Parameter
Remarks
The specified pulse width must be less or equal to the difference between
the period and the minimum pulse width. The U2761A will adjust the
pulse width as necessary to accommodate the specified period. Refer to
the U2761A USB Modular Function/Arbitrary Waveform Generator User’s
Guide for more information.
Examples
The following command sets the pulse width to 2 ms.
FUNC:PULS:WIDT 0.002
Item Type Range of values Default value
seconds Numeric 40 ns to 1999.99998 s 500 μs
SOUR : FUNC space
?
:PULS :WIDT seconds