Technical data

16 Error Messages
146 U2761A Programmer’s Reference
–221 Settings conflict; pulse width increased due to large period
The U2761A has adjusted the pulse width to the new minimum determined by the current period
–221 Settings conflict; pulse width decreased due to period
The U2761A has decreased the pulse width to accommodate the specified period
–221 Settings conflict; FSK hopping frequency changed due to function
The FSK hopping frequency is greater than the maximum frequency of the switched function
–221 Settings conflict; not able to set amplitude level for dc function
The U2761A is unable to generate an amplitude level for the DC function
–221 Settings conflict; not able to modulate pulse, modulation is turned off
The U2761A cannot generate a modulated waveform using the pulse function. The selected modulation
mode has been turned off.
–221 Settings conflict; not able to modulate dc, modulation turned off
The U2761A cannot generate a modulated waveform using the DC voltage function. The selected
modulation mode has been turned off.
–221 Settings conflict; not able to sweep pulse, sweep is turned off
The U2761A cannot generate a sweep using the pulse function. The sweep mode has been turned off.
–221 Settings conflict; not able to sweep dc, sweep turned off
The U2761A cannot generate a sweep using the DC voltage function. The sweep mode has been turned
off.
–221 Settings conflict; AM turned off by selection of other mode or modulation
The U2761A will allow only one modulation or sweep mode to be enabled at the same time
–221 Settings conflict; FM turned off by selection of other mode or modulation
The U2761A will allow only one modulation or sweep mode to be enabled at the same time
–221 Settings conflict; PM turned off by selection of other mode or modulation
The U2761A will allow only one modulation or sweep mode to be enabled at the same time
–221 Settings conflict; ASK turned off by selection of other mode or modulation
The U2761A will allow only one modulation or sweep mode to be enabled at the same time
–221 Settings conflict; FSK turned off by selection of other mode or modulation
The U2761A will allow only one modulation or sweep mode to be enabled at the same time
Tabl e 16-2 Execution errors (continued)