User's Manual

Performing Tests
RX Gain Test
Chapter 4
O:\Manuals\E6385A_Amps\Book\perftst.fm
80
Select and Run the Test
Select and run the RX Gain Test as follows:
Step 1. Take the affected radios and the amplifier to be tested out of service. Use a PC to dial
into the MSC and enter the craft shell, or call the MSC and instruct switch personnel as
to which radio to turn off.
Step 2. From the Lucent AMPS/TDMA Test Main Menu screen, select the Test Selections
field. The Test Software will display the Test Selections Menu screen.
Step 3. Select the RX Gain Test field. The Test Software will display the RX Gain Test screen.
Step 4. Select the Channel Number field. Enter the channel number of the radio by either
turning the knob to the desired number and pressing it, or using the DATA ENTRY keys
to enter the number, then either pressing the knob or the
Enter key to select it.
NOTE The number that you enter in the Channel Number field represents the output frequency
of the device to be tested.
In the case of a PCS Minicell, you must enter a channel number that sets the input
frequency of the RU to the proper 1900-MHz-band frequency to obtain the desired
850-MHz-band output frequency from the translator.
In the case of an 850-MHz Base Station, the input and output frequencies will be the
same.
Step 5. Select the Generator Output Level [dBm] field. Enter the signal level from the Test
Set into the amplifier by either turning the knob to the desired value and pressing it, or
using the DATA ENTRY keys to enter the value, then either pressing the knob or the
Enter key to select it.
CAUTION Make certain to enter a level in the Generator Output Level [dBm] field that will not
produce an output level greater than 60 milliwatts from the unit being tested. Input
levels to the ANT IN port greater than 60 milliwatts might damage the Test Set.
Step 6. Press the
k1 (Run) key. The Test Software will display a connection diagram.
Step 7. Connect two cables as shown in the connection diagram.
Step 8. Press the
k1 (Proceed) key. The Test Software will measure the losses through the test
cables, then display a second connection diagram.
Step 9. Connect the amplifier to be tested as shown in the second connection diagram.
Step 10. Press the
k1 (Proceed) key to perform the measurement.
Review the Results
The Test Software will display the gain and re-measure it continuously to allow for real
time adjustment.
Press the
k1 (Proceed) key to return to the RX Gain Test screen.