User's Manual

Performing Tests
Full Site Test (FCC)
Chapter 4
O:\Manuals\E6385A_Amps\Book\perftst.fm
66
Parameters and Specifications Used
The following parameters and specifications are used when running this test. See
Chapter 5, “Reference,” on page 95 for descriptions of the parameters and specifications.
Parameters:
1. Adjust TX Power [0=no 1=on fail 2=always]
3. GN Power Output [0=meas 1=spec 2=blnk]
The TX Coupling factor for the associated antenna(s) listed in the frequency plan
must be entered. This is done in parameters 22 through 28.
30. TX Test Port Cable Loss
Specifications (Pass/Fail Limits):
This test uses all specifications described in “Specifications (Pass/Fail Limits)” on page
124.
Select and Run the Test
Select and run the Full Site Test (FCC) as follows:
Step 1. Create a frequency plan for the radios to be tested (see “Defining a Frequency Plan” on
page 43).
Step 2. From the Lucent AMPS Test Main Menu screen, select the Test Selections field. The
Test Software will display the Test Selections Menu screen.
Step 3. Select the Full Site Test (FCC) field.
Step 4. Connect the Test Set to the Base Station as shown in the on-screen prompts.
Step 5. Press the
k1 [Proceed] key.
Review the Results
The Test Software will display test results for each radio as it tests. It provides prompts
at the top of the display to indicate the measurement or action currently being
performed. See Figure 4-4.