User's Manual
Quick Reference 1 
Series N5700 User’s Guide  13 
J2 Sense Connector 
1 – Remote sense (+) 
2 – Local sense (+) 
3 – Not used 
4 – Local sense (–) 
5 – Remote sense (–) 
The factory-shipped configuration is shown in the figure. 
SW1 Setup Switch 
The factory-shipped setting is Down for all switches. 
1 – Output voltage, voltage 
 programming 
Down
: The output voltage is programmed by the front panel. 
Up
: The output voltage is programmed by the external voltage signal. 
2 – Output current, voltage 
 programming 
Down
: The output current is programmed by the front panel. 
Up
: The output current is programmed by the external voltage signal. 
3 – Programming range 
 (voltage/resistance)  
Down
: The remote programming range is: 0 – 5V / 0 – 5KΩ. 
Up
: The remote programming range is: 0 – 10V / 0 – 10KΩ. 
4 – Voltage and Current 
 monitoring range 
Down
: The remote monitoring range is: 0 – 5V. 
Up
: The remote monitoring range is: 0 – 10V. 
5 – Shut-Off Logic Select  Down
: OUT OFF = Low (0 – 0.6V) or short; OUT ON = High (2V – 15V) or open. 
Up
: OUT OFF = High (2V – 15V) or open; OUT ON = Low (0 – 0.6V) or short. 
6 – Not Used    
7 – Output voltage, resistive 
 programming 
Down
: The output voltage is programmed by the front panel. 
Up
: The output voltage is programmed by the external resistor. 
8 – Output current, resistive 
 programming 
Down
: The output current is programmed by the front panel. 
Up
: The output current is programmed by the external resistor. 
9 – Enable/Disable control  Down
: The J1 Enable+/Enable– pins are not active. 
Up
: The J1 Enable+/Enable– pins are active. 
1
2
3
4
5
6
7
8
9