User's Manual
360
S:\agilent\8920\8920b\PRGGUIDE\BOOK\CHAPTERS\ibasic.fb  
Chapter 7, IBASIC Controller
Interfacing to the IBASIC Controller using Serial Ports
Interfacing to the IBASIC Controller using Serial Ports 
This section describes how to interconnect the Test Set to an external PC or 
terminal using the Test Set’s serial I/O ports. Program development methods #2 
and #3 use PC’s or terminals connected to the Test Set through the Test Set’s serial 
I/O ports. To determine which programming environment best fits your 
application, refer to 
“Choosing Your Development Method” on page 373. 
Test Set Serial Port Configuration 
To prepare for IBASIC program development, the Test Set must first be 
configured to operate with a PC or terminal. 
This includes,
• Hardware 
•Cables 
• Screens - I/O CONFIGURE and TESTS (IBASIC Controller) 
There are two independently controllable serial interfaces in the Test Set, each 
using a 3-wire transmit / receive / ground implementation of the RS232 standard. 
The IBASIC Controller can send and receive data from either port by using its 
assigned select code. 
Serial Port Information 
The Test Set’s rear-panel RJ-11 connector has 6 conductors. (Note that this jack 
appears the same as a common 4-conductor RJ-11 telephone jack, but the Test Set 
jack uses 6 conductors). Three of the wires are designated as Serial I/O Port 
address 9, and the other three wires are designated Serial I/O Port address 10 (also 
referred to as Serial Port B). These select codes cannot be changed. 