User's Manual
Table Of Contents
- Agilent Technologies 16750A/B Logic Analyzer
- Agilent Technologies 16750A/B Logic Analyzer
- Contents
- Getting Started
- Step 1. Connect the logic analyzer to the device under test
- Step 2. Choose the sampling mode
- Step 3. Format labels for the probed signals
- Step 4. Define the trigger condition
- Step 5. Run the measurement
- Step 6. Display the captured data
- For More Information...
- Example: Timing measurement on counter board
- Example: State measurement on counter board
- Task Guide
- Probing the Device Under Test
- Choosing the Sampling Mode
- To select transitional timing or store qualified
- Formatting Labels for Logic Analyzer Probes
- Setting Up Triggers and Running Measurements
- Displaying Captured Data
- Using Symbols
- Printing/Exporting Captured Data
- Cross-Triggering
- Solving Logic Analysis Problems
- Saving and Loading Logic Analyzer Configurations
- Reference
- The Sampling Tab
- The Format Tab
- Importing Netlist and ASCII Files
- The Trigger Tab
- The Symbols Tab
- Error Messages
- Must assign Pod 1 on the master card to specify actions for flags
- Branch expression is too complex
- Cannot specify range on label with clock bits that span pod pairs
- Counter value checked as an event, but no increment action specified
- Goto action specifies an undefined level
- Maximum of 32 Channels Per Label
- Hardware Initialization Failed
- Must assign another pod pair to specify actions for flags
- No more Edge/Glitch resources available for this pod pair
- No more Pattern resources available for this pod pair
- No Trigger action found in the trace specification
- Slow or Missing Clock
- Timer value checked as an event, but no start action specified
- Trigger function initialization failure
- Trigger inhibited during timing prestore
- Trigger Specification is too complex
- Waiting for Trigger
- Analyzer armed from another module contains no "Arm in from IMB" event
- Specifications and Characteristics
- Concepts
- Understanding Logic Analyzer Triggering
- Understanding State Mode Sampling Positions
- Getting Started
- Glossary
- Index

Index
227
patterns, 66
pause timer
, 79
performance verification, 108
period, sample
, 42
pod assignment dialog
, 57
pod clocking, demultiplex, 44
pod pairs, assigning
, 17
pod thresholds, setting
, 58
pods, assigning, 57
pods, specifying state clock
, 44
polarity, label
, 61
Port Out, using flags to drive, 81
positive logic
, 61
power through pod cables,
characteristic
, 186
predefined trigger functions
, 147
prefetch, triggering beyond
, 162
present for >, 78
preserving bit assignments
, 62
previous trigger setup, recalling
, 85
printing captured data, 104
probe leads
, 33
probes, general-purpose
, 13
probes, individual signal, 33
probing, overview
, 33
problems making measurements
,
108
processing of captured data,
canceling
, 94
pulse clear flag
, 81
pulse set flag
, 81
Q
qualifier, clock
, 14
qualifiers, clocks, characteristic,
186
R
R, bit assignment
, 59, 61
ranges, 66, 198
ranges and reordered bits
, 61
rate, sample
, 42
readers.ini file
, 101
recalling trigger setups
, 85
refining measurements, 11
re-importing captured data
, 104
relocating sections of code
, 97
renaming labels, 59
reordered bits
, 66
repetitive data display
, 92
repetitive group run, 86
repetitive run
, 86
replacing trigger sequence levels
,
73
replacing with a named event
, 84
reset counter
, 80
reset occurrence counter action,
83
results
, 162
resume timer, 79
run all
, 86
run repetitive
, 86
run single, 86
Run until user stop trigger
function
, 148, 151
S
sample period
, 14, 42, 116, 154
sample period, characteristic
, 186
sample rate, 1.25 ns
, 41
sample rate, 2.5 ns
, 41
sample rate, setting
, 36
samples, storing
, 71
sampling mode
, 36, 130
sampling mode, state
, 71
sampling modes
, 14
sampling position, automatic
adjustment
, 47, 132
sampling position, manual
adjustment
, 50, 144
sampling positions
, 43
sampling positions, eye finder
behavior
, 135
save/recall list (trigger), clearing
,
85
Save/Recall subtab, 157
saving trigger setups
, 85
Search Pattern field
, 162
searching captured data, 88
searching the symbol database
, 162
sections
, 166
Select Case statement, 198
selected sampling positions, eye
finder
, 135
selecting a trigger function, 65
self test
, 108
sequence (trigger), clearing
, 77
sequence level storage, 201
sequence levels
, 194
sequence levels, characteristic
, 186
sequence levels, cutting/copying-
and-pasting
, 74
sequence levels, inserting/
replacing/deleting
, 73
sequencer rate, fastest
, 41
sequencer, maximum levels,
characteristic
, 186
Serial Analysis tool
, 90
set flag
, 81
set up, trigger sequence, 74
Set/clear/pulse flag trigger
function
, 81, 149, 152
setting threshold voltages
, 58
settings (trigger), clearing
, 77
settings, eye finder advanced
, 133
settings, saving
, 110
Setup Assistant
, 13
setup time
, 208
setup/hold, 50, 144
setup/hold (logic analyzer)
, 43
setup/hold time, specification
, 186
setup/hold window, 47, 50, 132,
144, 208
single group run
, 86
single run, 86