User's Manual
Table Of Contents
- Agilent Technologies 16750A/B Logic Analyzer
- Agilent Technologies 16750A/B Logic Analyzer
- Contents
- Getting Started
- Step 1. Connect the logic analyzer to the device under test
- Step 2. Choose the sampling mode
- Step 3. Format labels for the probed signals
- Step 4. Define the trigger condition
- Step 5. Run the measurement
- Step 6. Display the captured data
- For More Information...
- Example: Timing measurement on counter board
- Example: State measurement on counter board
- Task Guide
- Probing the Device Under Test
- Choosing the Sampling Mode
- To select transitional timing or store qualified
- Formatting Labels for Logic Analyzer Probes
- Setting Up Triggers and Running Measurements
- Displaying Captured Data
- Using Symbols
- Printing/Exporting Captured Data
- Cross-Triggering
- Solving Logic Analysis Problems
- Saving and Loading Logic Analyzer Configurations
- Reference
- The Sampling Tab
- The Format Tab
- Importing Netlist and ASCII Files
- The Trigger Tab
- The Symbols Tab
- Error Messages
- Must assign Pod 1 on the master card to specify actions for flags
- Branch expression is too complex
- Cannot specify range on label with clock bits that span pod pairs
- Counter value checked as an event, but no increment action specified
- Goto action specifies an undefined level
- Maximum of 32 Channels Per Label
- Hardware Initialization Failed
- Must assign another pod pair to specify actions for flags
- No more Edge/Glitch resources available for this pod pair
- No more Pattern resources available for this pod pair
- No Trigger action found in the trace specification
- Slow or Missing Clock
- Timer value checked as an event, but no start action specified
- Trigger function initialization failure
- Trigger inhibited during timing prestore
- Trigger Specification is too complex
- Waiting for Trigger
- Analyzer armed from another module contains no "Arm in from IMB" event
- Specifications and Characteristics
- Concepts
- Understanding Logic Analyzer Triggering
- Understanding State Mode Sampling Positions
- Getting Started
- Glossary
- Index

Index
225
errors in data, 92
evaluation order
, 83
event evaluation order, 83
event list, naming
, 84
events
, 20, 78
events, counter, 80
events, flag
, 81, 149, 152
events, grouping
, 83
events, label edge, 66
events, label pattern
, 66
events, timer
, 79
eventual occurrence counts, 78
example
, 162, 163
expanding a trigger function
, 67
expansion frames, using flags, 81
exporting captured data
, 104
expressions, boolean
, 197
eye finder, 43, 47, 132, 208
eye finder advanced settings
, 133
eye finder data
, 110
eye finder selected/suggested
sampling positions
, 135
F
Feedthrough type, Port Out
, 81
File In tool, 104
File Out tool
, 104
file versions
, 96
files
, 96
Find 2 edges too close together
trigger function
, 149
Find 2 edges too far apart trigger
function
, 149
Find edge AND pattern trigger
function
, 148
Find edge trigger function
, 148
Find glitch trigger function
, 149
Find n-bit serial pattern, 151
Find Nth occurrence of an edge
trigger function
, 148
Find pattern n consecutive times,
152
Find pattern n times, 150
Find pattern occurring too late
after edge trigger function
,
149
Find pattern occurring too soon
after edge trigger function
,
149
Find pattern present/absent for &
,
148
Find pattern present/absent for >
duration trigger function
, 148
Find pattern trigger function, 148
Find pattern1 eventually followed
by pattern2
, 151
Find pattern2 n times after
pattern1, before pattern3
occurs
, 152
Find pattern2 occurring
immediately after pattern1
,
151
Find pattern2 occurring too late
after pattern1
, 151
Find pattern2 occurring too soon
after pattern1
, 151
Find too few states between
pattern1 and pattern2
, 151
Find too many states between
pattern1 and pattern2
, 151
Find width violation on a pattern/
pulse trigger function
, 148
finding the symbol you want
, 162
flag actions
, 81, 149, 152
flag events
, 81, 149, 152
flags
, 81, 199
flags, pod pair requirements in
state mode
, 178
flying lead set
, 13
for more information
, 24
format tab, 17
full channel, timing
, 41
full/half channel configuration
, 116
functions, 167
functions (trigger), advanced
, 153
functions (trigger), general state
,
150
functions (trigger), general timing,
148
functions, trigger
, 203
G
general state trigger functions
, 150
general timing trigger functions
,
148
general-purpose probes, 13
getting started
, 11
glitches
, 66
global counters, 80, 199
global markers
, 88
glossary of terms
, 2
group run repetitive, 86
group run single
, 86
group run with OR Trigger
, 150,
152
grouping events
, 83
H
half channel, timing
, 41
half/full channel configuration, 116
half-channel configuration
, 14
hard shutdown option
, 53
header connectors
, 13
help, symbols
, 159
high-level language source viewer
,
88
hold time
, 208
HSTL threshold level
, 58
humidity characteristics, 186
I
IEEE-695 file format
, 163
if branch
, 74
import, 121
importing previously exported
data
, 104
in ASCII format, 166, 167, 168, 169