User's Manual

134 Chapter 5
C:\Spk\Ref\RefGuideRevE\CdmascrnE2.fm
CDMA Measurements - Screens and Control Fields
CDMA Measurements
Figure 5-1 Rho
Screens on which this measurement is displayed
CDMA ANALYZER
CDMA GENERATOR
Estimated Rho (Est Rho)
Estimated rho is an calculated approximation of rho that is made
without taking the base station out of service.
Screens on which this measurement is displayed
CODE DOM (Code Domain Analyzer)
Frequency Error (Freq Err)
Frequency error is displayed when the Rho measurement is selected.
Frequency error is the difference between the base station’s transmitter
frequency and the frequency you enter in the Tune Freq field.
Screens on which this measurement is displayed
CDMA ANALYZER
CDMA GENERATOR
CODE DOM (Code Domain Analyzer)
Pow er that co rre lates with idea
l
Total Pow er
Signal Pow er
Signal Pow er + E rro r Pow er
ρ
ρ
=
=
ρ
>
0.912