User`s manual

Chapter 9 323
Error Messages
Numbered HP-IB Error Descriptions
Example 9-121 Error -1312
Data from RVC contains invalid bits in word [1,2,3].
Indicates that the decoded data received on the reverse voice channel
contains invalid bits in word 1 and/or word 2 and/or word 3. The raw
decoded data is displayed in hexadecimal format in the top right-hand
portion of the CALL CONTROL screen. Raw decoded data is only displayed
when the CALL CONTROL screen Display field is set to Data.
Example 9-122 Error -1313
Timeout occurred while in Maintenance state.
Indicates that the simulated Base Station’s internal timer expired
before the mobile station was taken out of the maintenance state. The
internal timer is set to 20 seconds when the maintenance order is sent
to the mobile station.
Example 9-123 Error -1314
Alert attempted while not in Maintenance or Connect state.
Indicates that an attempt was made to send an Alert order to the
mobile station when the Call Processing Subsystem was not in the
Maintenance state or Active state.
Example 9-124 Error -1315
Data from RECC contains invalid bits in word [1,2,3].
Indicates that the decoded data received on the reverse control channel
contains invalid bits in word 1 and/or word 2 and/or word 3. The raw
decoded data is displayed in hexadecimal format in the top right-hand
portion of the CALL CONTROL screen. Raw decoded data is only displayed
when the CALL CONTROL screen Display field is set to Data.