User`s manual
322 Chapter 9
O:\Manuals\E6380A_Progguid\Book\Errormsg.fm
Error Messages
Numbered HP-IB Error Descriptions
Example 9-116 Error -1307
Timeout occurred while attempting to register Mobile.
Indicates that the simulated Base Station’s internal timer expired
before receiving a response from the mobile station during a
registration attempt. The internal timer is set to 20 seconds when the
Register state is entered.
Example 9-117 Error -1308
Timeout occurred while attempting to page Mobile.
Indicates that the simulated Base Station’s internal timer expired
before receiving a response from the mobile station during a page
attempt. The internal timer is set to 20 seconds when the Page state is
entered.
Example 9-118 Error -1309
Timeout occurred while attempting to access Mobile.
Indicates that the simulated Base Station’s internal timer expired
before receiving a response from the mobile station during an access
attempt. The internal timer is set to 20 seconds when the Access state
is entered.
Example 9-119 Error -1310
Timeout occurred while attempting to alert Mobile.
Indicates that the simulated Base Station’s internal timer expired
before receiving a response from the mobile station during an alert
attempt. The internal timer is set to 20 seconds when the alert order is
sent to the mobile station.
Example 9-120 Error -1311
RF power loss indicates loss of Voice Channel.
When any Call Processing Subsystem screen is displayed (except the
ANALOG MEAS screen) and the Call Processing Subsystem is in the
Connect state, the host firmware constantly monitors the mobile
station’s transmitted carrier power. If the power falls below 0.0005
Watts the simulated Base Station will terminate the call and return to
the Active state. This error message is displayed if the host firmware
has detected that the mobile station’s carrier power has fallen below the
0.0005 Watts threshold. The call is dropped and the Call Processing
Subsystem returns to the Active state.