User`s guide

61
System Specifications
Amplitude Envelope Measurement Specifications
Amplitude Envelope Measurement Specifications
After one timeslot, 577 µs from an isolated receiver hop trigger in the GSM
frequency bands.
Input frequency setting range ± 10 kHz
Inaccuracy due to noise (for overshoots 1 dB)
Relative level
Input level setting error
± 1 dB ± 3 dB ± 3 dB with
5 averages
0 dB < ± 0.15 dB peak < ± 0.2 dB peak < ± 0.2 dB peak
-6 dB < ± 0.2 dB < ± 0.3 dB < ± 0.3 dB
-30 dB < + 3.0 dB < + 4.2 dB < + 2.2 dB
-3.8 dB -7.5 dB -2.6 dB