User`s guide
55
System Speciļ¬cations
RF Analyzer Speciļ¬cations
RF Analyzer Specifications
RF in/out connector
Frequency Range: 880 to 960 MHz and 1710 to 1990 MHz
Frequency Resolution: 1 Hz
Hop Mode Resolution: 100 kHz
Input Level range: -5 to +41 dBm (880 to 960 MHz)
-5 to +32 dBm (1710 to 1990 MHz)
Typical SWR: 1.5:1
10 MHz to 1 GHz Aux RF In connector (HP/Agilent 8922 connector)
Frequency Range: 10 MHz to 1 GHz
Frequency Resolution: 1 Hz
Hop Mode Resolution: 100 kHz
Input Level range: -36 to +20 dBm
1710 to 1990 MHz Aux RF In connector (HP/Agilent 83220A only)
1
Frequency Range: 1710 to 1990 MHz
Frequency Resolution: 1 Hz
Hop Mode Resolution: 100 kHz
Input Level range: -23 to +20 dBm
1. HP/Agilent 8922X, HP/Agilent 8922Y systems