TEST_06 TX Peak Power Error
Specifications
Parameters
Spec
no.
Description Units Default Lower
Limit
Default Upper
Limit
17 TX peak power error default power level dB This specification is now fixed in
the software. See page 120 for
details.
18 TX peak power error for pcl < 9 dB This specification is now fixed in
the software. See page 120 for
details.
39 Tx peak power error for pcl 9 dB This specification is now fixed in
the software. See page 136 for
details.
Parm
no.
Description Units GSM900
Default
Value
DCS1800
Default
Value
PCS1900
Default
Value
3 CP base station color code code no. 5.0 5.0 5.0
4 CP public land mobile network color code code no. 1.0 1.0 1.0
5 CP serving cell (BCH) ARFCN chan. no. 25.0 600.0 600.0
6 CP local area code code no. 1.0 1.0 1.0
7 CP mobile country code code no. 1.0 1.0 1.0
8 CP mobile network code code no. 1.0 1.0 1.0
9 CP control chan type [0=SD/8, 1=SD/4] 0 or 1 1.0 1.0 1.0
10 CP test with ciphering [0=no 1=yes] 0 or 1 0.0 0.0 0.0
11 CP delay(+) or advance() for trigger T 0.0 0.0 0.0
14 RT TCH [0=static 1=hopping 3 freqs] 0 or 1 0.0 0.0 0.0
15 RT cell TCH H.O. [0=inter 1=intra] 0 or 1 1.0 1.0 1.0
16 RT external pad and cable loss dB 0.0 0.0 0.0
20 RX RF level for signalling dBm 60.0 60.0 60.0
31 TX default power control level pcl 7.0 3.0 3.0
36 TX power level step for peak power pcl 4.0 4.0 4.0
37 TX power level sweep test start channel chan. no. 1.0 512.0 512.0
38 TX power level sweep test step channel chan. no. 62.0 187.0 149.0
39 TX power level sweep test stop channel chan. no. 124.0 885.0 810.0
47 CP System [0=GSM900, 1=DCS1800,
2=PCS1900, 3=E-GSM]
0, 1, 2 or 3 0.0 1.0 2.0
48 TX minimum power level for DCS1800 pcl 0.0 10.0 10.0