TEST_06 TX Peak Power Error
15 13 3.0 4.0
16 11 5.0 6.0
17 9 5.0 6.0
18 7 5.0 6.0
19
3
5 5.0 6.0
1. If power control level corresponds to the power class of MS, then the maximum
tolerances shall be 2.0 dB under normal measurement tolerances and 2.5 dB under
extreme measurement tolerances.
2. Extreme test condition tolerances are not used within the test software.
DCS1800/PCS1900 Test Limits
Power Class of
MS
Power Control
Level
Peak Power
(dBm)
Normal Test
Conditions
Tolerance (±dB)
Extreme Test
Conditions
Tolerance (±dB)
2
33034
3.0
1
4.0
1
31 32 3.0 4.0
10 30
3.0
1
4.0
1
1 28 3.0 4.0
22 26
3.0
1
4.0
1
3 24 3.0 4.0
4 22 3.0 4.0
5 20 3.0 4.0
6 18 3.0 4.0
7 16 3.0 4.0
8 14 3.0 4.0
9 12 4.0 5.0
10 10 4.0 5.0
11 8 4.0 5.0
12 6 4.0 5.0
13 4 4.0 5.0
14 2 5.0 6.0
15 0 5.0 6.0
1. If power control level corresponds to the power class of MS, then the maximum
tolerances shall be 2.0 dB under normal measurement tolerances and 2.5 dB under
extreme measurement tolerances.
2. Extreme test condition tolerances are not used within the test software.
GSM900 Test Limits
Power Class of
MS
Power Control
Level
Peak Power
(dBm)
Tolerance (±dB) for conditions
Normal
Extreme
2