Specifications
Chapter 2 61
Using Worksheets
WORKSHEETS FOR DUAL-BAND
WORKSHEETS FOR DUAL-BAND
The following worksheets are used for filling in Tests, Specifications,
and Parameters. Make copies of the worksheets before you write on
them.
Note that the Dual-Band test procedure uses parameters and
specifications from the GSM900 and DCS1800 test procedures.
NOTE
Each time a test procedure is selected, the list of tests (that is sequence)
assumes the values defined by that procedure.
DUAL-BAND TESTs worksheet for:
Step
no.
Test Description Specifications used Parameters used
TEST_01 MS Information − 1-12, 14, 16, 20, 31, 47
TEST_02 CP BS Originate − 1-12, 14, 16, 20, 31, 47
TEST_03 CP MS Originate − 3-12, 14, 16, 20, 31, 47
TEST_04 CP Speech Quality − 3-12, 14, 16, 20, 31, 47
TEST_05 TX In-channel Tests 6, 7, 17, 19-26, 36-38,
47
3-11, 14-16, 20, 31-35, 45, 47
TEST_06 TX Peak Power 17, 18, 39 3-11, 14-16, 20, 31, 36-39, 47,
48
TEST_07 TX ORFS Due to
Modulation
1
8-12 3-12, 14-16, 20, 31, 40, 41, 44,
47
TEST_08 TX ORFS Due to
Ramping
1
13-16 3-12, 14, 16, 20, 31, 47
TEST_09 RX Reference
Sensitivity (TCH/FS)
1-4 1-11, 14, 16, 21-28, 31, 47
TEST_10 RX Usable Input Level
Range
5 3-12, 14-16, 21, 22, 26-31, 47
TEST_11 RX Timebase Tuning
Range
2
7 3-11, 14-16, 18, 20, 31, 47
TEST_12 MS Quick Test 3, 6, 7, 18-26, 39 3-12, 16, 20, 22, 23, 31, 32, 47
TEST_13 MS Flow Chart − 3-12, 14-16, 20-25, 31, 47
TEST_14 TX RACH Test 27-35 11, 12, 31
TEST_15 CP End Call −−
TEST_16 Dual-Band Handover −−
TEST_04 CP Speech Quality − 3-12, 14, 16, 20, 31, 47
TEST_05 TX In-channel Tests 6, 7, 17, 19-26, 36-38,
47