Specifications
Chapter 2 59
Using Worksheets
WORKSHEETS FOR PCS1900
PCS1900 PARAMETERS worksheet for:
Used? Parm
no.
Description Units PCS1900
default
value
Value
1 AE IMSI (digits 1-5) number 0.00
2 AE IMSI number (digits 6-15) number 0.00
3 CP base station color code code no. 5.00
4 CP public land mobile network color code code no. 1.00
5 CP serving cell (BCH) ARFCN chann. no. 600.00
6 CP local area code code no. 1.00
7 CP mobile country code code no. 1.00
8 CP mobile network code code no. 1.00
9 CP control chan type [0=SD/8, 1=SD/4] 0 or 1 1.00
10 CP test with ciphering [0=no1=yes] 0 or 1 0.00
11 CP delay (+) or advance (-) for trigger T 0.00
12 RT default traffic channel [ARFCN 1-124] chann. no. 699.00
13 RT timeslot for TCH/FS[2,3,4,5,6] number 4.00
14 RT TCH [0=static 1=hopping 3 freqs] 0 or1 0.00
15 RT cell TCH H.O. [0=inter 1=intra] 0 or1 1.00
16 RT external pad and cable loss dB 0.00
17 RT nominal supply voltage Vdc 0.00
18
RT test set reference offset
1
ppm 0.05
19 RT report TCH uplink errors (0=off 1=on) 0 or 1 0.00
20 RX RF level for signalling dBm −60.00
21 RX loopback delay [0=autoset XX=value]
(frames)
0 or no. 0.00
22 RX BER/FER results [0=count 1=% 2=ppm] 0,1, or 2 1.00
23 RX RF level TCH/FS reference sensitivity dBm −102.00
24 RX bits to test reference sensitivity Ib bits 20000.00
25 RX bits to test reference sensitivity II bits 10000.00
26 RX ref sens sweep test start channel chann. no. 512.00
27 RX ref sens sweep test step channel chann. no. 298.00
28 RX ref sens sweep test stop channel chann. no. 810.00
29 RX usable input level range RF level dBm −23.00
30 RX bits to test usable input level II bits 10000.00
31 TX default power control level pcl 3.00
32 TX select in-channel tests XXXX 1111.00
33 TX in-channel sweep test start channel chann. no. 512.00