Specifications
Chapter 2 57
Using Worksheets
WORKSHEETS FOR PCS1900
PCS1900 SPECIFICATIONS worksheet for:
Used? Step
no.
Description Units PCS1900
default
lower
limit
PCS1900
default
upper
limit
Lower
limit
Upper
limit
1 RX ref sensitivity type Ib BER ct/%/
ppm
0.40
2 RX ref sensitivity type Ib FER fr/%/
ppm
0.10
3 RX ref sensitivity type II BER ct/%/
ppm
2.00
4 RX ref sensitivity type II FER fr/%/
ppm
0.10
5 RX usable input level type II
BER
ct/%/
ppm
0.10
6 TX burst timing measurement T −1.00 1.00
7 TX average frequency error Hz −190.00 190.00
8 TX ORFS due to mod 100 kHz
offset
1
dBc or
dBm
+0.5 dBc or
−32.00 dBm
n/a n/a
9 TX ORFS due to mod 200 kHz
offset
1
dBc or
dBm
−27.5 dBc
or −34.5
dBm
n/a n/a
10 TX ORFS due to mod 250 kHz
offset
1
dBc or
dBm
−32 dBc or
−35 dBm
n/a n/a
11 TX ORFS due to mod 400 kHz
offset
1
dBc or
dBm
−51 dBc or
−27 dBm
n/a n/a
12 TX ORFS due to mod ≥600 kHz
offset
1
dBc or
dBm
−60 dBc or
−56 dBm
n/a n/a
13 TX ORFS due to ramping 100
kHz offset
1
dBm −17.00 n/a n/a
14 TX ORFS due to ramping 600
kHz offset
1
dBm −22.00 n/a n/a
15 TX ORFS due to ramping 1200
kHz offset
1
dBm −30.00 n/a n/a
17 TX peak power error default
power level
dB
44
n/a n/a
18 TX peak power error for pcl <
9
2
dB
44
n/a n/a
19 TX average phase error (peak) degrees 20.00
20 TX average phase error (rms) degrees 5.00