Specifications
Chapter 2 48
Using Worksheets
WORKSHEETS FOR GSM900
22 TX power/time template ±18 µs dBc or
dBm
−30 dBc or
−17 dBm
n/a n/a
23 TX power/time template ±28
µs
1
dBc or
dBm
-59 dBc or
-36 dBm
n/a n/a
24 TX power/time template neg
peak flatness
dB −1.00
25 TX power/time template pos
peak flatness
dB 1.00
26 TX SACCH RX level error dB −3.00 3.00
27 TX RACH burst timing meas. T −1.00 1.00
28 TX RACH frequency error Hz −90.00 90.00
29 TX RACH peak power error dB
44
n/a n/a
30 TX RACH phase error (peak) degrees 20.00
31 TX RACH phase error (rms) degrees 5.00
32 TX RACH power/time temp.
±10 µs
dB
−6.00
3
n/a n/a
33 TX RACH power/time temp.
±18µs
dB −30 dBc or
−17 dBm
n/a n/a
34 TX RACH power/time neg.
peak flatness
dB −1.00
35 TX RACH power/time pos. peak
flatness
dB 1.00
36 TX worst case frequency error Hz −90.00 90.00
37 TX worst case phase error
(peak)
degrees 20.00
38 TX worst case phase error
(rms)
degrees 5.00
39
TX peak power error pcl ≥ 9
144
n/a n/a
1 HP/Agilent 8922 with Spectrum Analyzer Option 006 only
2 PCL (Power Control Level) refers to mobile TX level
3 For power control levels 16, 17 and 18 and above see page 123
4 Dependent on power control level, see page 123
GSM900 SPECIFICATIONS worksheet For:
Used? Step
no.
Description Units GSM900
default
lower
limit
GSM900
default
upper
limit
Lower
limit
Upper
limit