Specifications
Chapter 6 162
Test Parameters
Parameter descriptions
48 TX Minimum Power Level
This parameter allows you to choose the minimum power control level
(PCL) for peak-power measurements. Testing begins at the PCL set by
the parameter TX Default Power Control Level. The PCL
increments by the value entered in the parameter TX Power Level
Step for Peak Power, and ends at the value set by TX Minimum
Power Level. The range is:
• 1 to 19 for GSM and E-GSM
• 30, 31 and 0 to 15 for PCS
• 0 to 15 for DCS
Default value • 15 for GSM and E-GSM
• 10 for DCS/PCS
Example If you wanted to test a radio with a minimum power level of 13 (Power
Class 2), you would enter 13 in the value field.
49 TX Power Level Control for TEST_08
This parameter sets the power control level that is used for the ORFS
test number 8.
Default value • 10 for GSM
• 5 for DCS/PCS
Error message If you set a higher pcl than the default, then the following error
message is displayed at the start of the test:
ORFS due to ramping tests above PCL 10/5 are not
recommended due to the limited dynamic range. Please
reconfigure parameter 49.
NOTE
Only GSM power classes 4 and 5, and DCS/PCS power classes 1 are
supported for ORFS tests (TEST_07 and TEST_08). If parameter 49 is
in the range of 0 to 4 for GSM, or 29 to 31 for DCS/PCS, then the test
does not execute and produces the following error message:
Power control level not supported by this test. Please
reconfigure parameter 49.