Specifications

Chapter 6 150
Test Parameters
Parameter descriptions
23 RX RF Level TCH/FS Reference Sensitivity
This parameter sets the amplitude of the RF signal to be used when
testing the receiver’s reference sensitivity (bit error testing). The range
is
12 dBm to 127 dBm.
Default value The default RF level for sensitivity testing is
102 dBm for GSM900.
The default RF level for sensitivity testing is
100 dBm for DCS1800.
The default RF level for sensitivity testing is
102 dBm for PCS1900.
Example If you want the RF level to be set at
104 dBm, you would enter 104 in
the value field.
NOTE
The HP/Agilent 8922F and HP/Agilent 8922H are specified to a
maximum RF Generator amplitude limit of
13 dBm, whereas the HP/
Agilent 8922E and HP/Agilent 8922G are specified to a maximum RF
Generator amplitude limit of
19 dBm. However, a 7dB overrange is
provided on all HP/Agilent 8922s.
24 RX Bits to Test Reference Sensitivity Ib
This parameter sets the number of residual type Ib bits to test during
reference sensitivity testing. The range is 0 to 99999999.
Default value The default number of type Ib bits to test is 20000.
Example If you want sensitivity testing to occur over 50,000 residual type Ib bits,
you would enter 50000 in the value field.
25 RX Bits to Test Reference Sensitivity II
This parameter sets the number of residual type II bits to test during
reference sensitivity testing. The range is 0 to 99999999.
Default value The default number of type II bits to test is 10000.
Example If you want sensitivity testing to occur over 40000 residual type II bits,
you would enter 40000 in the value field.