Specifications
Chapter 5 125
Test Specifications
26 TX SACCH RX Level Error
26 TX SACCH RX Level Error
Description This specification sets the limits for testing the mobile station’s
reported RX level error on the SACCH (Slow Associated Control
Channel).
If a selected limit is exceeded, an “F” (for fail) will be displayed next to
the SACCH RX Level error results.
Default value The default value for the lower limit is
−3.0 dB. The default value for
the upper limit is 3.0 dB.
Example If you want your test procedure to report a failure when the reported
RX Level error exceeds
±2.5 dB, you would enter −2.5 in the lower-limit
column and 2.5 in the upper-limit column. Limits are entered in dB.