Specifications
Chapter 5 123
Test Specifications
21 — 23 TX Power/Time Template
±
10, 18, and 28
µ
s
21 — 23 TX Power/Time Template ±10, 18,
and 28 µs
Description These specifications set the amplitude limits for measurements taken
relative to bit 0 of the burst.
NOTE
Measurements at ±28 µs require an HP/Agilent 8922G or HP/Agilent
8922 with Spectrum Analyzer Option 006.
If a selected limit is exceeded, an “F” (for fail) is displayed next to the
TX ampl envelope measurement result.
Hardcoded
values
The hardcoded values are as follows:
Example To be defined showing how the table of hardcoded values gets applied
during the test.
10µsec 18µsec -28 µsec +28 µsec
GSM900 -6dBc -30dBc or -17dBm
whichever is
greater
-59dBc or -36dBm
whichever is
greater
-59dBc or -54dBm
whichever is
greater
Except level = 16 -4dBc
Except level =17 -2dBc
Except level ≥ 18 -1dBc
DCS1800/PCS1900 -6dBc -30dBc or -20dBm
whichever is
greater
-48dBc or -48dBm whichever is greater
Except level = 11 -4dBc
Except level = 12 -2dBc
Except level = ≥ 13 -1dBc