Specifications

Chapter 5 116
Test Specifications
7 TX Average Frequency Error
7 TX Average Frequency Error
Description This specification sets the pass/fail limits for measuring the mobile
station transmitter’s frequency error.
If a selected limit is exceeded, an “F” (for fail) is displayed next to the TX
N avg frequency err measurement result, where N is the number of
averages set in parameter RX BER/FER results.
NOTE
”Average”, in phase and frequency error measurements, only applies
when parameter TX phase/freq measurement averages is not set
to its default value of 1.
Default values The GSM900 default lower limit value is
90 Hz. The GSM900 default
upper limit value is 90 Hz. The DCS1800 default lower limit value is
180 Hz. The DCS1800 default upper limit value is 180 Hz. The
PCS1900 default lower limit value is
190 Hz. The PCS1900 default
upper limit value is 190 Hz.
Example If you want your test procedure to report a failure if the average
frequency error from the mobile station transmitter exceeds
±95 Hz for
GSM 900,
±185 Hz for DCS1800, and ±195 Hz for PCS1900, you would
enter
95 (185 or 195) in the lower-limit column and 95 (185 or 195)
in the upper-limit column. Limits are in units of Hz.