Specifications

Chapter 4 102
Tests
TEST_13 MS Flow Chart
Parameters
Parm
no.
Description Units GSM900
Default
Value
DCS1800
Default
Value
PCS1900
Default
Value
3 CP base station color code code no. 5.0 5.0 5.0
4 CP public land mobile network color code code no. 1.0 1.0 1.0
5 CP serving cell (BCH) ARFCN chan. no. 25.0 600.0 600.0
6 CP local area code code no. 1.0 1.0 1.0
7 CP mobile country code code no. 1.0 1.0 1.0
8 CP mobile network code code no. 1.0 1.0 1.0
9 CP control chan type [0=SD/8, 1=SD/4] 0 or 1 1.0 1.0 1.0
10 CP test with ciphering [0=no 1=yes] 0 or 1 0.0 0.0 0.0
11 CP delay(+) or advance() for trigger T 0.0 0.0 0.0
12 RT default traffic channel [ARFCN 1-124] chan.no. 62.0 699.0 699.0
14 RT TCH [0=static 1=hopping 3 freqs] 0 or 1 0.0 0.0 0.0
15 RT cell TCH H.O. [0=inter 1=intra] 0 or 1 1.0 1.0 0.0
16 RT external pad and cable loss dB 0.0 0.0 0.0
20 RX RF level for signalling dBm 90.0 90.0 90.0
21 RX loopback delay [0=autoset XX=value]
(frames)
0 or number 0.0 0.0 0.0
22 RX BER/FER results [0=count 1=%
2=ppm]
0, 1, or 2 1.0 1.0 1.0
23 RX RF level TCH/FS reference sensitivity dBm 102.0 100.0 102.0
24 RX bits to test reference sensitivity Ib bits 20000.0 20000.0 20000.0
25 RX bits to test reference sensitivity II bits 10000.0 10000.0 10000.0
31 TX default power control level pcl 7.0 3.0 3.0
47 CP System [0=GSM900, 1=DCS1800,
2=PCS1900, 3=E-GSM]
0, 1, 2 or 3 0.0 1.0 2.0