Specifications

Chapter 4 93
Tests
TEST_09 RX Reference Sensitivity (TCH/FS)
Parameters
Parm
no.
Description Units GSM900
Default
Value
DCS1800
Default
Value
PCS1900
Default
Value
1 AE IMSI (digits 1-5) number 0.0 0.0 0.0
2 AE IMSI number (digits 8-15) number 0.0 0.0 0.0
3 CP base station color code code no. 5.0 5.0 5.0
4 CP public land mobile network color
code
code no. 1.0 1.0 1.0
5 CP serving cell (BCH) ARFCN chan. number 25.0 600.0 600.0
6 CP local area code code no. 1.0 1.0 1.0
7 CP mobile country code code no. 1.0 1.0 1.0
8 CP mobile network code code no. 1.0 1.0 1.0
9 CP control chan type [0=SD/8,
1=SD/4]
0 or 1 1.0 1.0 1.0
10 CP test with ciphering [0=no 1=yes] 0 or 1 0.0 0.0 0.0
11 CP delay(+) or advance() for trigger T 0.0 0.0 0.0
14 RT TCH [0=static 1=hopping 3 freqs] 0 or 1 0.0 0.0 0.0
16 RT external pad and cable loss dB 0.0 0.0 0.0
21 RX Loopback delay [0=autoset
XX=value] (frames)
0 or number 0.0 0.0 0.0
22 RX BER/FER results [0=count 1=%
2=ppm]
0, 1, or 2 1.0 1.0 1.0
23 RX RF level TCH/FS reference
sensitivity
dBm 102.0 100.0 102.0
24 RX bits to test reference sensitivity
Ib
bits 20000.0 20000.0 20000.0
25 RX bits to test reference sensitivity II bits 10000.0 10000.0 10000.0
26 RX tests sweep start channel chan. number 1.0 512.0 512.0
27 RX tests sweep step channel chan. number 124.0 373.0 298.0
28 RX tests sweep stop channel chan. number 124.0 885.0 810.0
31 TX default power control level pcl 7.0 3.0 3.0
47 CP system [0=GSM900, 1=DCS1800,
2=PCS1900, 3=E-GSM]
0, 1, 2 or 3 0.0 1.0 2.0