User`s guide

17-4
Fast Bit Error Test
RFGenerator:ATSLot
RFGenerator:ATSLot
Description Sets/Queries the automatic pulse modulation for the adjacent timeslots of the base station
generated signal.
Syntax FBETest:RFGenerator:ATSLot?
FBETest:RFGenerator:ATSLot <string>
Options ‘OFF’ | ‘+30DB’
Where +30DB automatically pulses the adjacent timeslots 30 dB higher than the
RF generator amplitude setting.
The entire preceding timeslot is 30 dB higher. The first few bits for the
following timeslot are 30 dB higher. The remainder of the following
timeslot is pulsed off.
OFF makes all timeslots the same amplitude.
NOTE This field is not featured in the Agilent 8922S.