User`s guide
13-4
DISPlay Subsystem
CELL:TCH[:SELect]
CELL:TCH[:SELect]
Description Selects/queries which TCH parameters to display on the Cell Control screen.
Syntax DISPlay:CELL:TCH[:SELect]?
DISPlay:CELL:TCH[:SELect] <string>
Options ‘TCH1’ | ‘TCH2’
DSPanalyzer:AMPLitude:MASK
Description Selects/queries whether the DSP analyzer AMPLitude MASK should be DISPlayed on the
’AMPL MID’, ’AMPL RISE’ and ’AMPL FALL’ screen VIEWs.
Syntax DISPlay:DSPanalyzer:AMPLitude:MASK?
DISPlay:DSPanalyzer:AMPLitude:MASK <string>
Options ‘ON’ | ‘OFF
DSPanalyzer:AMPLitude:MASK:PCS
Description This command is for use only with the 83220A/E GSM Test Set. It selects/queries whether
the DSP analyzer AMPLitude MASK in PCS 1900 mode should be off, the old ETSI
Phase 1 mask (narrow) or the new ETSI Phase II mask (relaxed).
Syntax DISPlay:DSPanalyzer:AMPLitude:MASK:PCS?
DISPlay:DSPanalyzer:AMPLitude:MASK:PCS <string>
Options ‘OFF”|’NARROW’|’RELAX’
NOTE The DISPlay:DSPanalyzer:AMPlitude:MASK <string> command has the following effect
on the PCS1900 PvT mask for the two values of <string>.
‘OFF’ turns the mask off
‘ON’ sets the mask to the default value NARROW
DSPanalyzer:VIEW
Description Selects/queries the VIEW to be selected when DISPlay:SCReen DSPanalyzer is selected.
Syntax DISPlay:DSPanalyzer:VIEW?
DISPlay:DSPanalyzer:VIEW <string>
Options ’PHASEMAIN’ | ’PHASE ERR’ | ’AMPL MAIN’ |
’AMPL MID’ | ’AMPL RISE’ | ’AMPL FALL’ | ’DATA BITS’