User`s guide

10-16
Configure Subsystem
SPORt:STOP
SPORt:STOP
Description Selects/queries the STOP length - the number of stop bits used when using the Serial PORt.
Syntax CONFigure:SPORt:STOP
CONFigure:SPORt:STOP <string>
Options ‘1 BIT’ | ‘2 BITS’
SPORt:XPACe
Description Selects/queries the Serial PORt PACe when transmitting (TX) serial data.
Syntax CONFigure:SPORt:XPACe?
CONFigure:SPORt:XPACe <string>
Options ’XON/XOFF’ | ’NONE’
Where;
XON/XOFF lets the receiving device ’talk’ to the instrument to alter the rate of the data
being sent.
NONE disable the XON/XOFF function.
TIME
Description Sets/queries the TIME of day for the instruments clock.
Syntax CONFigure:TIME?
CONFigure:TIME <real> | [:INUM]
Options Refer to Appendix A.
Format = HH.MM in 24 Hour format.