User`s guide
9-19
Cell Control Subsystem
MS:DRX[:STATe]
MS:DRX[:STATe]
Description Selects/queries the Discontinuous RX (receiver) STATe.
Syntax CELL:MS:DRX[:STATe]?
CELL:MS:DRX[:STATe] <string>
Options ’ON’ | ’OFF’
MS:DTX[:STATe]
Description Selects/queries the Discontinuous TX (transmission) STATe.
Syntax CELL:MS:DTX[:STATe]?
CELL:MS:DTX[:STATe] <string>
Options ’ON’ | ’OFF’
MS:TADVance
Description Selects/queries the MS’s Timing ADVance (setting).
Syntax CELL:MS:TADVance?
CELL:MS:TADVance <integer> | [:INUM]
Options Refer to Appendix A.
MS:TADVance:MODE
Description Selects/queries the MS’s Timing ADVance (setting) MODE.
Syntax CELL:MS:TADVanceMODE?
CELL:MS:TADVance:MODE <string>
Options ‘AUTO’ | ‘MANUAL’
Where;
• AUTO means we will automatically adjust the MS’s timing advance setting in real time
to keep bit zero aligned.
• MANUAL means the TADVance setting will directly set the MS’s timing advance
setting.