User`s guide

7-5
Bit Error Test Commands (Measure Subsystem)
BERRor:IRATio
BERRor:IRATio
Description Sets CRC Intermediate RATio MEASurement attributes. Queries the CRC Intermediate
RATio
GPIB units are % (PCT), PPM;
default unit is PPM.
Display units are % (PCT), PPM;
default unit is PPM.
NOTE: This can only be queried when in the state
TRIGger:BETest:MODE ‘RUN’
Syntax MEASure:BETest:BERRor:IRATio<n>?
MEASure:BETest:BERRor:IRATio<n>[:MM] | [:AVG]
Options where <n> = 1..4.
Refer to Appendices D and F.
BERRor:RATio
Description Sets Bit Error RATio MEASurement attributes. Queries the Bit ERRor RATio
GPIB units are % (PCT), PPM;
default unit is PPM.
Display units are % (PCT), PPM;
default unit is PPM.
Syntax MEASure:BETest:BERRor:RATio<n>?
MEASure:BETest:BERRor:RATio<n>[:MM] | [:AVG]
Options where <n> = 1..4.
Refer to Appendices D and F.
BTESted
Description Queries the number of Bits TESted for the completed Bit ERRor Test measurements
Syntax MEASure:BETest:BTESted<n>?
Options where <n> = 1..4.