Chapter 3: Testing Performance
Test Pod 1 in the 1500 Mb/s mode
bottom of the oscilloscope display. It is displayed as “=”.
10 In the logic analyzer “Setup and Trigger...” window, select the Sampling
tab. In the “State Mode Controls” section, select the “1500 Mb/s / 128M
Half Chan” mode.
11 In the logic analyzer’s Setup and Trigger window, Format tab, unassign all
pod 2 bits.
12 Assign bits 2, 6, 10, and 14 of Pod 1.
13 Ensure that the Pod 1 threshold is set to 1 volt. See page 53.
14 In the “Setup and Trigger...” window, Format tab, ensure that the J clock
threshold is still set to Differential.
15 Re-establish the trigger function:
a In the logic analyzer’s Setup and Trigger window, select the Trigger tab,
and the Trigger Functions subtab.
b Select “Find pattern n times” and select the “Replace” button.
c Enter “A” in the “Label 1 = “ field.