Specifications

79
Chapter 5: Troubleshooting
To test the cables
region. If not, see “To re-align a stray channel” on page 46.
7 Select OK to close the Sample Positions window.
8 Select OK to close the Analyzer Setup window.
9 Switch to the Listing window by selecting the Listing tab at the bottom of
the main window.
10 Select the Run icon .
11 Data will appear in the Listing Window upon completion of the run.
12 If the listing shows that the data alternates between AAAA and 5555, then
the probe and cable pass the test.
If the listing does not look similar to the figure, then there is a possible problem
with the cable or probe tip assembly. Causes for cable test failures include:
open channel.
channel shorted to a neighboring channel.
channel shorted to either ground or a supply voltage.