Technical data

SOURce Commands SCPI Commands Reference
Agilent 81133A/81134A Pulse Generator Programming Guide, March 2007 45
SOURce Commands
The following table shows the Agilent 81133A/81134A Pulse
Generator SOURce commands:
Command Parameter Description
[:SOURce]
:FUNCtion
[:SHAPe][?] PATTern|
BURSt, <numeric>|
RBURSt, <numeric>,
<numeric>
Sets/reads instrument
mode
:MODE[1|2][?] PULSe|SQUare|
DATa|PRBS
<numeric>
Sets instrument main
mode
:FREQuency
[:CW|:FIXed][?] Numeric
[GHz|MHz|kHz|Hz] |
MIN|MAX
Sets/reads internal
clock frequency
:PHASe
[:ADJ][1|2][?] Numeric|MIN|MAX
Sets/reads channel
phase
[:PULSe]
:DCYCle[1|2][?] Numeric|MIN|MAX
Sets/reads channel duty
cycle
:DELay[1|2][?] Numeric
[ps|ns|us|ms|s] |
MIN|MAX
Sets/reads channel de-
lay
:DESKew[1|2][?] Numeric
[ps|ns|us|ms|s]|
MIN|MAX
Sets/reads channel
deskew
:DHOLd[1|2][?] DELay|PHASe
Holds Delay|Phase fixed
with varying frequency
:PERiod[?] Numeric
[ps|ns|us|ms|s] |
MIN|MAX
Sets/reads internal
clock period
:POLarity[1|2][?] NORMal|
COMPlement|
INVerted
Sets/reads channel
polarity
:WIDTh[1|2][?] Numeric
[ps|ns|us|ms|s] |
MIN|MAX
Sets/reads channel
width