:OUTPut[0|1|2]:DIVider
Syntax
:OUTP[0|1|2]:DIV[?]
Form Set & Query
Description This command is used to program the frequency divider
parameters of the trigger output (0) and the channel outputs (1,
2).
The trigger output frequency is divided only when the trigger
output is in Pulse mode (
:OUTPut0:SOURce PERiodic
).
You can program the divider in Data mode (
:OUTPut0:SOURce
BITstream
) but it will have no effect until you select the trigger
output to pulse mode.
The channel output frequency is divided in square and pulse
pattern mode only (
[SOURce]:FUNCtion:MODe[1|2] SQUare
|
PULSe
).
You can program the divider in data and PRBS pattern mode
(
[SOURce]:FUNCtion:MODe[1|2] DATa|PRBS
), but it will have no effect
until you select the square or pulse pattern mode.
Parameter Numeric|MIN|MAX
*RST value 1
Specified Limits For trigger output (channel 0): 1 ... 2
31
– 1
For channels 1 and 2: 1, 2, 4, 8, 16, 32, 64, 128
Example Set Trigger Output Divider to 8.
:OUTP0:DIV 8