Programming instructions

48
Using the Agilent 81101A
The Mode/Trigger Screen
Triggered Pulses Mode
The following figure shows typical timings for trigger mode TRIGGERED
and pulse mode PULSES. The pulses are triggered by the rising edge of
the arming source.
Characteristics
Single pulse periods are triggered by (T
RG
'
D
BY
) an active edge at the
selected arming source:
MAN key on front panel, triggered by press or release or both.
EXT INPUT triggered by rising or falling or both edges.
You can select single pulses or double pulses per pulse period.
TRIGGER OUT marks each pulse period.
STROBE OUT is not used in triggered pulse mode.
NOTE
The PLL cannot be selected as the arming source. Select continuous
pulse mode with the PLL as period source to achieve the same result.
OUTPUT
OUTPUT
TRIGGER OUT
Arming Source
Trg'd by: Ext Input or MAN Key
Single Pulses
Double Pulses
STROBE OUT
Trg'd by: